11/2006

11

www.U-LineService.com

CO1175 — Ice Maker/Refrigerator

Leveling Information

IMPORTANT

It is extremely important that the unit is level. If it is not 
level, the ice mold will not fill evenly.

1. Use a level to check the 

levelness of the unit from 
front to back and from 
side to side. Level should 
be placed along top edge 
and side edge as shown 
(see 

Figure 20

).

2. If the unit is not level, adjust the feet on the corners of 

the unit as necessary (see 

Figure 21

).

3. Check the levelness after each adjustment and repeat 

the previous steps until the unit is level. Go on to 

9 Install the Unit

.

Installation Tip

If the room floor is higher than the floor in the cut-out 
opening, adjust the rear feet to achieve a total unit rear 
height of 1/8" less than the opening’s rear height. Shorten 
the unit height in the front by adjusting the front feet. 
This allows the unit to be gently tipped into the opening. 
Readjust the front feet to level the unit after it is correctly 
positioned in the opening.

Installation of the CO75A

1. Open the water supply valve in the main water source.

2. Plug in the power cord.

3. Gently push the unit into position. Be careful not to 

kink the water supply line or entangle the electrical 
cord. 

4. Re-check the leveling, from front to back and side to 

side. Make any necessary adjustments. The unit’s top 
surface should be approximately 1/8" below the 
countertop.

Grille Installation

1. Locate and remove the grille screw from the cabinet, 

using a standard blade screwdriver (or a 1/4" 
nutdriver). See 

Figure 22

.

.

2. Remove the control knob by pulling it away from the 

cabinet.

3. Identify the grille screw hole on the grille itself. It is 

located toward the top of the middle recessed section 
of the grille.

4. Place the two hook-hinges (located on the rear bottom 

side of the grille) onto the front lip of the unit base. 
Swing the grille up into position, aligning the grille 
screw hole on the grille to the grille screw hole on the 
cabinet. See 

Figure 23

.

8 Level the Unit

Figure 20

ULIN_0818_A

1

Turn Foot to Adjust

Figure 21

9 Install the Unit

Grille Screw

Figure 22

Summary of Contents for Origins CO1175AS

Page 1: ...rvice com Phone 414 354 0300 FAX 414 354 7905 Service Parts Tech Lines Phone 800 779 2547 FAX 414 354 5696 OnlineService U Line com 2006 U Line Corporation 11 2006 CO1175 Ice Maker Refrigerator Instal...

Page 2: ...is unit requires connection to the water supply Improper hook up can result in substantial property damage If you are unsure of your ability to safely connect the water supply to the unit consult a li...

Page 3: ...ion parts Complete and mail the Product Registration Card or register online at www U LineService com Once your unit is installed keep the User Manual and this Installation Guide in a safe place for f...

Page 4: ...olors or rusting appears clean it quickly with Bon Ami or Barkeepers Friend Cleanser and a non abrasive cloth Always clean in the direction of the grain Always finish this process with Claire Stainles...

Page 5: ...next to a wall or similar type of structure All left hand hinged units require a minimum of 1 4 door clearance if installed flush with cabinet or wall and 8 clearance for Black Stainless Steel units i...

Page 6: ...rt screw and reinstall pivot screw in hinge See Figure 6 7 Install bottom hinge on cabinet opposite side aligning flat edge of hinge with outer edge of unit Partially tighten screws See Figure 8 8 Rel...

Page 7: ...ries units side by side CO1175 1175R Refrigerator or 1175WC Wine Captain Note that each Side By Side Installation will be different Cut out width for a side by side installation is the total of the wi...

Page 8: ...Use care when handling the insert Insert edges may be sharp 1 Remove top hinge screw pin with a Phillips head screwdriver Remove door by tilting forward and lifting off bottom hinge pin 2 Pull door g...

Page 9: ...ttom hinge screws 4 Tighten top hinge screws Go on to 6 Prepare Plumbing CAUTION Plumbing installation must observe all state and local codes All water connections MUST BE made by a licensed qualified...

Page 10: ...5 Go on to 7 Prepare Power Supply Electrical Specifications CAUTION Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized re...

Page 11: ...e unit after it is correctly positioned in the opening Installation of the CO75A 1 Open the water supply valve in the main water source 2 Plug in the power cord 3 Gently push the unit into position Be...

Page 12: ...n 4 and 5 Assure that setting was not altered in shipment No other adjustments should be necessary at this time For information about Adjusting the Temperature Control see the User Manual As soon as t...

Page 13: ...Solution A Check that the water is connected and turned on and the line is not obstructed Water coming into the unit may take an hour or more Problem Q The cubes produced during the first two to three...