background image

www.U-LineService.com

8

11/2006

CO1175 — Ice Maker/Refrigerator

Units will accept a Custom 1/4" Thick Insert to harmonize 
with or accent the surrounding decor. 

If this treatment is not included in this installation, go on 
to 

5 Adjust Door

.

Custom 1/4'' Thick Door Panel Insert

Door Panel Preparation

A custom door panel can be inserted into the doorframe. 
Custom door panels can be flat or raised, as long as the 
maximum panel thickness where inserted into the door 
reveal (channel) is 1/4"-thick. For raised panels, the depth 
of the reveal is 1/4" on all four sides.

IMPORTANT

Raised panels will reduce the door’s 90° swing/zero 
clearance if the unit is installed next to a wall or similar 
type of structure (see 

Page 5

).

Cut the panel insert to the following dimensions.

Custom 1/4" Dimensions 

for Black units:

Width:

22-15/16"

Height:

26-15/16"

The door panel must not weigh more than 20 lbs.

Door Panel Installation

Install the insert as follows:

CAUTION

Use care when handling the insert. Insert edges may be 
sharp.

1. Remove top hinge screw pin with a Phillips head 

screwdriver. Remove door by tilting forward and lifting 
off bottom hinge pin.

2. Pull door gasket out of 

groove (top edge of door 
only). Start in the middle 
and pull outward, moving 
toward the edge (see 

Figure 13

). This may take 

some force.

3. Remove two outside 

screws holding door 
handle. Slightly separate 
door handle from door 
(see 

Figure 14

).

4. Pull handle up and off.

IMPORTANT

Use care not to bend light switch bracket (where 
installed), located on door bottom when installing door 
insert. Do not set door on bottom edge when pushing 
insert into place.

5. Slide custom door panel insert into 1/4-inch channel in 

door front.

6. Holding door gasket out of the way, replace handle on 

door, making sure it is seated properly on insert and 
that screw holes line up.

7. Install two small screws removed in

 Step 3

.

8. Starting at the corners and working inward, push door 

gasket into place on door.

9. Place door on bottom hinge pin and install upper hinge 

screw.

10. Go on to 

5 Adjust Door

.

4 Prepare and Install Door Panel

Figure 12

Figure 13

Figure 14

Summary of Contents for Origins CO1175AS

Page 1: ...rvice com Phone 414 354 0300 FAX 414 354 7905 Service Parts Tech Lines Phone 800 779 2547 FAX 414 354 5696 OnlineService U Line com 2006 U Line Corporation 11 2006 CO1175 Ice Maker Refrigerator Instal...

Page 2: ...is unit requires connection to the water supply Improper hook up can result in substantial property damage If you are unsure of your ability to safely connect the water supply to the unit consult a li...

Page 3: ...ion parts Complete and mail the Product Registration Card or register online at www U LineService com Once your unit is installed keep the User Manual and this Installation Guide in a safe place for f...

Page 4: ...olors or rusting appears clean it quickly with Bon Ami or Barkeepers Friend Cleanser and a non abrasive cloth Always clean in the direction of the grain Always finish this process with Claire Stainles...

Page 5: ...next to a wall or similar type of structure All left hand hinged units require a minimum of 1 4 door clearance if installed flush with cabinet or wall and 8 clearance for Black Stainless Steel units i...

Page 6: ...rt screw and reinstall pivot screw in hinge See Figure 6 7 Install bottom hinge on cabinet opposite side aligning flat edge of hinge with outer edge of unit Partially tighten screws See Figure 8 8 Rel...

Page 7: ...ries units side by side CO1175 1175R Refrigerator or 1175WC Wine Captain Note that each Side By Side Installation will be different Cut out width for a side by side installation is the total of the wi...

Page 8: ...Use care when handling the insert Insert edges may be sharp 1 Remove top hinge screw pin with a Phillips head screwdriver Remove door by tilting forward and lifting off bottom hinge pin 2 Pull door g...

Page 9: ...ttom hinge screws 4 Tighten top hinge screws Go on to 6 Prepare Plumbing CAUTION Plumbing installation must observe all state and local codes All water connections MUST BE made by a licensed qualified...

Page 10: ...5 Go on to 7 Prepare Power Supply Electrical Specifications CAUTION Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized re...

Page 11: ...e unit after it is correctly positioned in the opening Installation of the CO75A 1 Open the water supply valve in the main water source 2 Plug in the power cord 3 Gently push the unit into position Be...

Page 12: ...n 4 and 5 Assure that setting was not altered in shipment No other adjustments should be necessary at this time For information about Adjusting the Temperature Control see the User Manual As soon as t...

Page 13: ...Solution A Check that the water is connected and turned on and the line is not obstructed Water coming into the unit may take an hour or more Problem Q The cubes produced during the first two to three...