11/2006
7
www.U-LineService.com
CO1175 — Ice Maker/Refrigerator
Water Supply
The unit requires a 1/4-inch OD water supply line and a
shutoff valve. For more information see
Page 9
.
Environmental Requirements
The surrounding air temperature must be at least 50°F
(10°C) but must not exceed 110°F (40°C). Units may be
installed outdoors in a covered area. The unit must not be
located near heat-generating equipment or in direct
sunlight.
Side-By-Side Installation
Instructions
For a complete refreshment center, install two of the
following 1175 series units side by side: CO1175, 1175R
Refrigerator or 1175WC Wine Captain
®
. Note that each
Side-By-Side Installation will be different.
• Cut-out width for a side-by-side installation is the total
of the widths listed under
Cut-Out Dimensions
in each
unit’s Installation Guide.
For example:
Placing a CO1175 next to another 1175 series unit
would require a cut-out width of:
24-3/16" + 24-3/16" = 48-3/8"
• No trim kit is required. However, 1/4-inch space needs to
be maintained between the units to ensure
unobstructed door swing.
• Units must operate from separate, properly grounded
electrical receptacles placed according to each unit’s
Electrical Specifications
.
7"
4"
34-1/4"
to
35-1/8"
1/4" Space
Between
Appliances
24"
Figure 11
Typical Side-By-Side Cut-Out