PAGE 3 OF 9
0621 IH-6432
Figure 1
5. Hold the fixture housing (2) firmly and connect
the green ground wire from the fixture to the bare
copper ground wire from the junction box using
a wire nut (3). (If house wiring does not include a
ground wire, consult your local electrical code for
approved grounding methods).
6. Use wire nuts (3) to connect the black fixture wire to
the black power supply wire and the white (neutral)
fixture wire to the white power supply wire.
NOTE: For proper connection, place wire nut
over wires and twist clockwise until tight.
7. Hold fixture housing (2) in one hand, and with the
other hand, position wires up into junction box.
8. Align keyholes on back of fixture housing with
screws previously installed in junction box. Lift fixture
up, rotate clockwise and tighten screws to secure
housing assembly against ceiling.
9. To install diffuser (4), starting at one end of housing,
insert diffuser slot onto edge of housing. Carefully
squeeze diffuser to engage opposite side with
housing. Continue this action down length of diffuser
until fully installed onto housing. (See Figure 1)
10. Turn on electricity at fuse or circuit breaker box and
verify success of installation.
TROUBLESHOOTING GUIDE
If this fixture fails to operate properly, use the guide
below to diagnose and correct the problem.
• Verify that fixture is wired properly.
• Verify that fixture is grounded correctly.
• Verify that the line voltage at the fixture is correct.
If further assistance is required, contact Uline Customer
Service.
This LED light provides low maintenance service with no
bulbs to change.
Cleaning Diffuser: For best results, diffusers should be
washed with soap or mild detergent. Rinse with clear
water and allow to air dry.
ASSEMBLY CONTINUED