background image

CLR2060 — Clear Ice Maker

www.U-LineService.com

18

02/2005

Installation Troubleshooting

Problem

Q:

Water is leaking under the unit.

Solution

A:

A water leak under the unit is most likely caused by a bad 
connection in the water supply line. Make sure the water 
line’s brass fitting is screwed tight to its valve and 
threaded correctly. Make sure the fill tube’s connection to 
the water line is also tight. Check drain line to make sure 
it has not been disconnected from drain connection on 
back of the unit or disconnected from the drain.

Problem

Q:

The door remains open unless it is pushed closed.

Solution

A:

The hinges should be self-closing when the door is open 
approximately 8". If this is not the case, make sure the 
closers (at the bottom of the hinge pin) are clean, greased 
and installed correctly. Also, re-check leveling from front 
to back of the unit and readjust if necessary. Make sure 
that pivot plate is installed correctly.

Problem

Q:

The custom overlay door was designed to align with the 
rest of the cabinet doors, but the unit has crept forward.

Solution

A:

First, make sure that the electrical cord and water supply 
line are not obstructing the installation. If they are not, 
there is mostly likely not enough room allowed for the 
drain connection on the rear of the unit. You may need to 
alter the wall behind the unit to accommodate the drain 
connection.

Initial Start-Up

Once installation and leveling is complete, the unit is 
ready for initial start-up and operation. The cycle selector 
switch is located in the front grille (see 

Figure 45

). 

1. Open the door and remove the cover in front of the 

evaporator by gently compressing and pulling 
forward. This will enable you to observe the water 
flow over the evaporator.

2. Check that the overflow tube is inserted securely into 

the water trough.

3. Put the cycle selector switch (in the grille) in the ICE 

position (press the switch up). The water fill valve will 
energize and fill the water reservoir. The water fill valve 
shuts off after approximately 180 seconds (3 minutes). 
The compressor begins to operate.

10 Start-Up for the First Time

C

 

E

O

 

F

C

 

L

 

N

C

 

E

O  F

 

F

N

Cycle Selector

Switch

Figure 45

Summary of Contents for ECHELON CLR2060

Page 1: ...eService com Phone 414 354 0300 FAX 414 354 7905 Service Parts Tech Lines Phone 800 779 2547 FAX 414 354 5696 OnlineService U Line com 2005 U Line Corporation 02 2005 CLR2060 Clear Ice Maker Installat...

Page 2: ...of your ability to safely connect the water supply to the unit consult a licensed plumber for assistance This unit requires connection to a drain Improper connection can result in substantial propert...

Page 3: ...User Manual and this Installation Guide in a safe place for future reference Your unit is Black White or Stainless Steel Black and White units have a reversible door with a slightly contoured handle...

Page 4: ...acent cabinet doors in certain installations you may need to alter the wall just behind the drain connection on the unit to accommodate the drain The actual amount of alteration will be determined by...

Page 5: ...mount on opposite side BOTTOM see Figure 7 4 Remove the two door closer inserts from the existing bottom hinge and install as shown on the new bottom hinge see Figure 8 5 Remove existing bottom hinge...

Page 6: ...tdoor use by UL The unit must not be located near heat generating equipment or in direct sunlight Side By Side Installation Instructions For a complete refreshment center install your CLR2060 Clear Ic...

Page 7: ...ation Install the insert as follows CAUTION Use care when handling the insert Insert edges may be sharp 1 Remove top hinge screw pin 7 64 Allen wrench or Phillips screwdriver depending on your unit s...

Page 8: ...k corner of overlay panel Refer to Figure 16 for exact specifications Route notch in top corner of overlay panel as shown see Top and Side Views Top of notch is entire depth of panel front to back Wid...

Page 9: ...4 Remove the top handle and discard This handle will be replaced with the Modified Handle included in the Full Overlay Door Panel Kit 5 Remove the two screws located on both sides of the lower handle...

Page 10: ...wo screws removed in Step 5 under Removing Existing Door 3 Starting at the corners and working toward the center push the door gasket back into place Installing the Door 1 Remove the existing hinges f...

Page 11: ...gned the door should be 1 8 below the top of the unit s cabinet NOT flush with the top see Figure 26 1 Compare the top edge of the door to the top edge of the cabinet 2 If the door edge is 1 8 below a...

Page 12: ...actor Failure to follow recommendations and instructions may result in damage and or harm Drain Connection IMPORTANT Drain can NOT be located directly below unit Unit has a solid base that will not al...

Page 13: ...ons requiring a Drain Pump If you need to install a P60 Drain Pump into your unit see Locally Installed Drain Pump on Page 14 IMPORTANT Before installing your U Line CLR2060 with Factory Installed U L...

Page 14: ...e back of the unit to a 5 8 inch OD rigid tube using a worm clamp 2 Attach the other end of the rigid tube to your 5 8 inch ID drain line with a worm clamp 3 Insulate the drain line if necessary to pr...

Page 15: ...ation U Line recommends the use of copper tubing for installation To connect to water supply 1 Install the 1 4 inch OD copper water line from the main water source see Figure 37 2 Locate the compressi...

Page 16: ...e more easily serviced with self diagnostics without disturbing your installation WARNING SHOCK HAZARD Electrical Grounding Required Never remove the round grounding prong from the plug and never use...

Page 17: ...feet This allows the unit to be gently tipped into the opening Readjust the front feet to level the unit after it is correctly positioned in the opening Installation of the CLR2060 1 Open the water su...

Page 18: ...to align with the rest of the cabinet doors but the unit has crept forward Solution A First make sure that the electrical cord and water supply line are not obstructing the installation If they are no...

Page 19: ...leshooting Problem Q Unit does not appear to turn on when switch is set to ICE Solution A Remember that the compressor will not operate until the water has been filling for about 3 minutes Make sure u...

Page 20: ...U Line has distinguished itself as the leader in built in undercounter ice making refrigeration and wine storage appliances Who to Call Service Information If the need for service arises contact the d...

Reviews: