General Precautions

Use this appliance for its intended purpose only and 
follow these general precautions along with those listed 
throughout this guide:

WARNING

SHOCK HAZARD — Electrical Grounding Required. 

• Keep the unit unplugged throughout installation 

except during testing.

• Never remove the round grounding prong from 

the plug and never use a two-prong grounding 
adapter.

• Never use an extension cord to connect power to 

the unit.

• Always keep your working area dry. 

CAUTION

• Use care when moving and handling the unit. Use 

gloves to prevent personal injury from sharp edges.

• Do not lift the unit by the door or door handle.

• Do not install the unit behind closed doors or in any 

way that would obstruct airflow to the front grille, 
which may cause the unit to malfunction.

You have received a carton containing your CLR2060 Clear 
Ice Maker with a package inside containing a User Manual, 
a Product Registration Card and water connection parts. 
Complete and mail the Product Registration Card or 
register online at www.U-LineService.com. Once your unit 
is installed, keep the User Manual and this Installation 
Guide in a safe place for future reference.

Your unit is Black, White or Stainless Steel. Black and 
White units have a reversible door with a slightly 
contoured handle across the top. They come with a flush 
mounted door panel that, when removed, will accept a 
custom 1/4-inch thick door panel or a 3/4-inch thick full 
overlay door panel. Stainless Steel units are covered with 
a protective coating and have been ordered left- or right-
hand hinged. The Stainless doors are not reversible and 
do not accept custom panels. CLR2060 Clear Ice Makers 
may be ordered with a factory-installed drain pump. 
Please carefully follow the directions that apply to your 
unit and your intended design.

Tools/Materials Required

• 7/64" Allen wrench

• Screwdrivers — slotted and Phillips head

• 1/4-inch OD copper tubing and shut-off valve for water 

supply line

• 5/8-inch ID drain line

• P60 Drain Pump (if required and not already factory 

installed, see 

Page

 

12

)

• 1/4-inch thick door panel material and cutting tools 

(Black or White units)

• Full Overlay Door Panel Kit (part number U-OL2015B — 

Black or part number U-OL2015W — White), 3/4-inch 
door panel overlay, cutting tools, drill and bits (Black or 
White units)

Inspection

Unwrap and inspect the unit on a flat, level surface 
capable of supporting its entire weight.

2 Inspect and Plan

Summary of Contents for ECHELON CLR2060

Page 1: ...eService com Phone 414 354 0300 FAX 414 354 7905 Service Parts Tech Lines Phone 800 779 2547 FAX 414 354 5696 OnlineService U Line com 2005 U Line Corporation 02 2005 CLR2060 Clear Ice Maker Installat...

Page 2: ...of your ability to safely connect the water supply to the unit consult a licensed plumber for assistance This unit requires connection to a drain Improper connection can result in substantial propert...

Page 3: ...User Manual and this Installation Guide in a safe place for future reference Your unit is Black White or Stainless Steel Black and White units have a reversible door with a slightly contoured handle...

Page 4: ...acent cabinet doors in certain installations you may need to alter the wall just behind the drain connection on the unit to accommodate the drain The actual amount of alteration will be determined by...

Page 5: ...mount on opposite side BOTTOM see Figure 7 4 Remove the two door closer inserts from the existing bottom hinge and install as shown on the new bottom hinge see Figure 8 5 Remove existing bottom hinge...

Page 6: ...tdoor use by UL The unit must not be located near heat generating equipment or in direct sunlight Side By Side Installation Instructions For a complete refreshment center install your CLR2060 Clear Ic...

Page 7: ...ation Install the insert as follows CAUTION Use care when handling the insert Insert edges may be sharp 1 Remove top hinge screw pin 7 64 Allen wrench or Phillips screwdriver depending on your unit s...

Page 8: ...k corner of overlay panel Refer to Figure 16 for exact specifications Route notch in top corner of overlay panel as shown see Top and Side Views Top of notch is entire depth of panel front to back Wid...

Page 9: ...4 Remove the top handle and discard This handle will be replaced with the Modified Handle included in the Full Overlay Door Panel Kit 5 Remove the two screws located on both sides of the lower handle...

Page 10: ...wo screws removed in Step 5 under Removing Existing Door 3 Starting at the corners and working toward the center push the door gasket back into place Installing the Door 1 Remove the existing hinges f...

Page 11: ...gned the door should be 1 8 below the top of the unit s cabinet NOT flush with the top see Figure 26 1 Compare the top edge of the door to the top edge of the cabinet 2 If the door edge is 1 8 below a...

Page 12: ...actor Failure to follow recommendations and instructions may result in damage and or harm Drain Connection IMPORTANT Drain can NOT be located directly below unit Unit has a solid base that will not al...

Page 13: ...ons requiring a Drain Pump If you need to install a P60 Drain Pump into your unit see Locally Installed Drain Pump on Page 14 IMPORTANT Before installing your U Line CLR2060 with Factory Installed U L...

Page 14: ...e back of the unit to a 5 8 inch OD rigid tube using a worm clamp 2 Attach the other end of the rigid tube to your 5 8 inch ID drain line with a worm clamp 3 Insulate the drain line if necessary to pr...

Page 15: ...ation U Line recommends the use of copper tubing for installation To connect to water supply 1 Install the 1 4 inch OD copper water line from the main water source see Figure 37 2 Locate the compressi...

Page 16: ...e more easily serviced with self diagnostics without disturbing your installation WARNING SHOCK HAZARD Electrical Grounding Required Never remove the round grounding prong from the plug and never use...

Page 17: ...feet This allows the unit to be gently tipped into the opening Readjust the front feet to level the unit after it is correctly positioned in the opening Installation of the CLR2060 1 Open the water su...

Page 18: ...to align with the rest of the cabinet doors but the unit has crept forward Solution A First make sure that the electrical cord and water supply line are not obstructing the installation If they are no...

Page 19: ...leshooting Problem Q Unit does not appear to turn on when switch is set to ICE Solution A Remember that the compressor will not operate until the water has been filling for about 3 minutes Make sure u...

Page 20: ...U Line has distinguished itself as the leader in built in undercounter ice making refrigeration and wine storage appliances Who to Call Service Information If the need for service arises contact the d...

Reviews: