background image

Installation and User’s Manual 

 

BLMI-300A 
BLMI-500A
BLMI-650A

BLMI-900A

ver.201803_02

I512A-200

Summary of Contents for BLMI-300A

Page 1: ...InstallationandUser sManual BLMI 300A BLMI 500A BLMI 650A BLMI 900A ver 201803_02 I512A 200 ...

Page 2: ... to Remove Machine Panel 2 6 Bin Installation 2 7 Bin S W Installation 2 8 Water supply Drain Connections 2 9 Wire 2 10 Final Check 2 11 Test Run 3 Operation 18 3 1 Button 3 2 Status Light 3 3 7 Segments 3 4 Operation Cycle 3 5 Safety 3 6 Error Codes 4 Maintenance Cleaning 22 4 1 Maintenance Period 4 2 Interior Cleaning Sanitizing Procedure 4 2 1 Cleaning Procedure 4 2 2 Sanitizing Procedure 4 2 3...

Page 3: ... hours af delivery After 24 hours the seller is not responsible for any freight damage incurred Keep the product as well as all of the original packaging material in a receiving area for carrier s inspection Warning Connect to potable water supply only Adult Supervision is required for safe use either by children under 8 years of age or the developmentally disabled The warranty does not apply to t...

Page 4: ...N A Sanitation Approval ETL N A N A Energy Star Certified N A N A CE N A Certified N A KC N A N A Certified 500A Condenser Air Cooling Rated Voltage 115V 60Hz 1Ph 220 240V 50Hz 1Ph 220V 60Hz 1Ph Rated Ampere 14A 7A 7A Compressor 115 V 57 LRA 11 4RLA 198 254V 18 6LRA 4 04RLA 198 254V 30 0LRA 4 35 RLA Pump 115V 0 53FLA 59 9W 220 230V 0 16FLA 35 9W 220 230V 0 2FLA 41 3W Fan 115V 0 68FLA 75 2W 220 230...

Page 5: ... Sanitation Approval ETL N A N A Energy Star Certified N A N A CE N A Certified N A KC N A N A Certified 900A Condenser Air Cooling Rated Voltage 208 230V 60Hz 1Ph 220 240V 50Hz 1Ph 220V 60Hz 1Ph Rated Ampere 9A 9A 9A Compressor 208 230V 41LRA 7 6RLA 220V 50LRA 9 4 RLA 208 230 V 48 LRA 8 8RLA Pump 115V 0 55FLA 63 5W 230V 50Hz 0 29FLA 61 7W 220V 60Hz 0 28FLA 61 0W Fan 115V 0 68FLA 75 2W 220 230V 0 ...

Page 6: ...7lbs day 235 kg day 5 500A 220 240V 50Hz 1Ph 463lbs day 210 kg day 6 500A 220V 60Hz 1Ph 457lbs day 208 kg day 7 650A 208 230V60Hz 1Ph 625lbs day 283 kg day 8 650A 220 240V 50Hz 1Ph 726lbs day 329 kg day 9 650A 220V 60Hz 1Ph 643lbs day 292 kg day 10 900A 208 230V60Hz 1Ph 890lbs day 404 kg day 11 900A 220 240V 50Hz 1Ph 858lbs day 389 kg day 12 900A 220V 60Hz 1Ph 915lbs day 415 kg day Approximate Ice...

Page 7: ...1 2 Product Dimensions 300A 500A 7 FRONT TOP SIDE REAR ...

Page 8: ...8 650A FRONT TOP SIDE REAR ...

Page 9: ...9 900A FRONT TOP SIDE REAR ...

Page 10: ... ice production in pound a 4 digits CIS code for specific model b 1 digit Product group c 2 digits Manufacturing site supplier code d 1 digit Manufacturing year e 1 digit Manufacturing month f 5 digit Serial number 00001 99999 BL Blueair M Modular U Undercounter I Crescentice Air cooled a b d e f c Year 2015 2016 2017 2018 2019 2020 Mark G H J K M N Month Jan Feb Mar Apr May Jun Mark 1 2 3 4 5 6 M...

Page 11: ...ine filled with ice The head and bin should be level The vent of the of ice machine and drain of the bin should be separated The drain tip of the bin should have an air gap The ice machine and bin should be completely cleaned after installation The drain line should be easily separated from the ice machine There must be minimum of 8 inches 20 cm of clearance around above and below the machine for ...

Page 12: ...Electrical wiring and ground must be done by a qualified electrician Installation condition Condition Minimum Maximum Ambient Temperature F 45 100 C 7 38 Water temperature F 45 90 C 7 32 Water pressure psig 30 100 kPa 206 8 689 4 Voltage 115V 100 130 220V 208 230 2 3 1 Voltage 2 3 2 Fuse Circuit Breaker When operating the ice machine with maximized electrical load range of variation in maximum vol...

Page 13: ...ine To avoid any damage during installation remove all panels Please refer to 2 5 How to Remove Panel Remove all accessories enclosed with the ice machine Remove protective plastic film on the panel Check whether a compressor is secure and the fan blade turns freely The ice machinemustbe installed onto the bin The available binsare as below LB 300S 30 inch 762mm LB 220S 22 inch 558mm For further i...

Page 14: ...nt panel by firmly grasping the bottom edge and pulling it up and away from the unit 3 Store the front panel securely 4 Remove the top panel by firmly grasping the front edge and pushing back 5 Store the top panel securely 6 Unscrew the Side Panel R and store it away securely 7 Grasp the front of the right panel and pull it forward 8 Store the right panel securely 9 The left and back panels cannot...

Page 15: ...ure the bin is level by adjusting the legs on the bin 4 Attach the ice machine head onto the bin 5 Attach the ice machine head to the bin at two points on the back with the enclosed brackets and screws 2 6 Bin Installation WARNING Please check whether the ice machine and ice storage bin are compatible before installation The ice machine and bin should be properly attached together Fig 2 MODUALR BR...

Page 16: ... Position the cable of bin switch into the J type slot of the front supporter by releasing it While installing the cable ensure it is not blocking any ice are dropping into the bin 5 After affixing the cable alongside the Pump motor harness connect it to the blue connector at the top frame 2 7 Bin Switch Installation WARNING Bin switch should be equipped before operating the ice machine If it is n...

Page 17: ...line For adequate drainage a gradient of 1 inch for every 3 3 feet 2 5cm per meter is needed Do not install any trap Do not connect drainage pipe directly into the sewage pipe There must be a minimum of a 2 inch 50cm air gap vertically between end of the drainage pipe and the drain hole Must install a vent Do not combine drain lines for the machine head and the ice storage bin The machine applies ...

Page 18: ... Fig 4 Conditions for water supply and drainage Location Water temperature Water pressure connecting fitting size Size of connecting hose Water inlet 7 C 45 F Min 32 C 90 F Max 30 psig 206 9kPa Min 100 psig 689 4kPa Max 3 8 FPT ID 1 4 copper pipe Min Drain 3 4 FPT ID 3 4 Hard pipe Min ...

Page 19: ...firmly grasping the plug Power connection should be at least 7 8 diameter and have a 1 2 screw size conduit Permanently connect The green ground wire in the factory installed power cord is connected to a screw on the bracket where the cord enters the machine If it becomes necessary to remove or replace the power cord be sure to connect the power cord s ground wire to this screw upon reattachment C...

Page 20: ...of the bin switch Full will be disappeared and the ice machine goes into the water supply procedure The ice machine will stop operation immediately if you press flap for 10 seconds within 5 minutes after initiating ice making cycle If not the ice machine will stop after completion of ice making and harvest cycle 1 Is ambient temperature of the installation area within the appropriate temperature r...

Page 21: ...range light will appear If water level is too low red light will appear 2 Clean Green light will appear during washing mode 3 Err Red light will appear if any problems occur during the machine operation 4 Freeze Green light will appear during freezing cycle 5 Harvest Green light will appear during harvest 3 Operation When turning off the unit during a testrun please do not attempt to re operate un...

Page 22: ... Elapsed time min 3 Freezing Period 00 Elapsed time min Drainage cycle Wash mode Ice machine is either cleaning or sanitizing Indicates when the bin is full of ice Wash mode Indicates need to put detergent or sanitizer into the machine Cleaning and saitization completed User has to press the button to remove this sign ...

Page 23: ...ber of cycles completely drain leftover water in the water tank by using water pump 1 Maximum freezing time 60min To protect the ice machine maximum freezing time is set to 60 minutes When freezing cycle goes over 60 minutes it switches to the harvesting cycle During the second freezing cycle if time goes over 60 minutes machine stops and shows error code E1 on the control panel with a beep sound ...

Page 24: ...ature sensing error Ambient or water temperature too low A T 45 100 F 7 38 C W T 45 90 F 7 32 C Voltage 115V 100 130V 220V 208 230V Voltage too high or too low E3 Evaporator temp too high temp 140 For 60 C Water temperature too high W T 45 90 F 7 32 C Sensor or connector defect PCB defect E4 No drainage when the bin is full Check water outlet hose Check pump motor Level Sensor not operating E5 Wat...

Page 25: ...h compressed air or warm water and allow to fully dry Every month Water filter system Check proper water pressure and replace filter if needed Ice machine exterior Clean with spot free water and soft cloth Bottom of ice machine bin door Wipe it with a soft fabric Every six months Ice machine Ice storage bin Wash and sanitize according to the manual Please refer to 4 2 How to clean and sanitize Wat...

Page 26: ... complete and turn off ice machine by holding the Power button for 2 seconds 2 Remove all ice from the storage bin 3 Press the Wash button 4 Machine will display drn on the control board and drain any remaining water in the water trough If machine doesn t detect any water draincycle will be skipped and control board will move on to step 5 5 Once all water has drained from machine control board wil...

Page 27: ...s from step 15 of cleaning instructions in prepared sanitizing solution for 5 minutes 4 Sanitize ice machine food zones where evaporator is installed and storage bin with sanitizing solution 5 Let sanitized parts dry completely 6 Reassemble disassembled parts referring to 4 2 3 Modular Ice machine disassembly 7 Press the Wash button 8 Machine will display drn on the control board and drain any rem...

Page 28: ...ation top and front after detaching cover top and cover front Refer to 2 5 Panel disassembly for detailed instruction 3 Release thumb screw in the cabinet by referring to above image Top Cover Front Cover Top Insulator Front Insulator Thumb Screw ...

Page 29: ...Grip the Guide Ice Upper and push it to the rear Pull it out through the left Pull out the Guide Ice Upper 5 Release the bolt fixed on the Ice Cover Pull out the Ice Cover Ice Cover Guide Ice Upper only 300A ...

Page 30: ...30 6 Pull out the parts to disassemble them in order of Water Cover and Guide Ice 7 Disassemble the clamps to detach the hoses Water Cover Guide Ice Hose ...

Page 31: ...rews fixed on Level sensor and Pump motor and separate the Level sensor and Pump Motor 9 Pull out the parts in order of SprayTube SupplyTube and Spray Guide to disassemble them SprayTube SupplyTube Spray Guide Pump Motor ...

Page 32: ...sor Cleaning 1 Refer to 2 5 How to Remove Panel to separate the Ice Cover from body 2 In order to drain out water inside the cabinet completely detach Pump Hose as shown in the mage 3 Disassemble Level Sensor refer to Front Cover in the Removal and replacement chapter 4 Separate the parts in order of Connector Stopper Float and Body referring to image 5 Wash contamination inside of Connector and B...

Page 33: ...er and Check buttons for 2 seconds at the same time to drain remaining water inside of the machine 4 drn will display and once the remaining water level minimum level the machine stop drain 5 Disconnect the host connects water tank and pump motor to drain all remaining water inside of the unit Instruction can be found on 4 2 3 Modular Product Disassembly 6 Disconnect power code and lock water supp...

Page 34: ...MEMO 34 ...

Page 35: ...MEMO 35 ...

Page 36: ...BLUEAIR FSE LLC Gardena CA 90248 Tel 866 677 8500 310 808 0102 Fax 310 808 0242 310 808 0262 Visit us our website at www blueairinc com ...

Reviews: