SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE •
SERVICE
Control Operation - Service 8
USER GUIDE
u-line.com
or
To exit the Factory Wi-Fi menu press to select
“Return to Menu” and press
to confirm outputs.
Set Points
The Set points menu contains options to modify both
the Zone and Evap set points. Changes to the zone
set point will be reflected on the main screen.
Changes to the evap set point alter the temperature
the evaporator needs to meet during a defrost cycle.
To access Set Points
1.
Press
to select “Set Points”.
2.
Press
3.
Press to scroll through
available set points.
To change set points
4.
Press
, the selected set point will begin to
flash.
5.
Press to modify the value.
6.
Press
to confirm setting.
To exit the Set Points menu, press
to select “Return
to Menu” and press
to confirm.
Fan Delay
The Fan Delay menu option allows the modification of
fan run times during and after a cooling cycle. In
order to allow time for the evaporator to properly
cool, the evaporator fan is delayed from starting with
the cooling cycle for a given amount of time. In order
to remove as much warmth as possible from the
cabinet the evaporator fan will continue to run at the
end of the cooling cycle for a given amount of time.
Fan Delay On=
“Fan Delay On” is the amount of time in minutes the
fan will be delayed from starting from the beginning
of a cooling cycle.
Fan Delay Off=
“Fan Delay Off” is the amount of time in minutes the
fan will continue to run at the end of a cooling cycle.
To access Fan Delay
1. Press
to
select “Fan Delay”.
2.
Press .
To change fan delay
3.
Press
to select either “Fan Delay On” or “Fan
Delay
Off” and press
. The chosen option will begin
to flash.
4.
Press
or
to change settings.
5.
Press
to confirm.
To exit Fan Delay, press
to select “Return to Menu”
and press
to confirm.
Up
Select
Down
RETURN TO MENU
SET POINTS
ZONE = 3°C
EVAP = 5°C
Up
Select
Down
RETURN TO MENU
FAN DELAY
FAN DELAY ON = 1
FAN DELAY OFF = 2
.
and