10
tytan
Column 8 shows the status of optional equipment: RF module with analogue central door
lock control outputs and external sensor No2 inputs
Lamp
Description
RMT_LOCK
The lamp shows that LOCK button on Tytan remote transmitter was
pressed
RMT_UNLOCK
The lamp shows that UNLOCK button on Tytan remote transmitter was
pressed
RMT_TRUNK
The lamp shows that UNLOCK_TRUNK button on Tytan remote
transmitter was pressed
OUT_LOCK
The lamp shows that the central door locking analogue control output on
RF module is active - connected to ground
OUT_UNLOCK
The lamp shows that the central door unlocking analogue control output
on RF module is active - connected to ground
Press the
GPS/GSM
Signal
button to open the panel with GSM signal strength (CSQ), the
information if the GSM is registered in the GSM network, GPS signal quality (HDOP) and
GPS data: latitude and longitude. The green colour shows the values which are correct for
the device to operate; red colour shows the values which are insufficient for the device
to operate correctly.
Parameter
Description
GSM registered
Value 1 means that the device is correctly registered in the GSM
network.
GSM CSQ
GSM signal strength. Value 0 is weakest. Value 31 is strongest. Value
99 means no signal. Value >5 is sufficient
GPS HDOP
GPS signal quality. Value <35 is sufficient
GPS longitude
GPS position: longitude
GPS latitude
GPS position: latitude
Press the
Alarm Memory
button. The panel with alarm memory displays last 3 alarm trigger
sources. The memory can be cleared by pressing the ‘Clear’ button.
If the DS512 is equipped with optional RF module, press the
RF module
button. The test
panel with 2 controls is opened.
The
Save remote
transmitters
button starts programming procedure of Tytan remote
transmitters.
The
RF module monitor
control confirms reception of transmission from
all remote transmitters programmed into RF module. After receiving
transmission from any remote transmitter, the control lights up red for a
second and number of the remote in the RF memory is presented.
Moreover, the controls from the eight column (RMT_LOCK,
RMT_UNLOCK, RMT_UNLOCK) of signal monitor can be used to test
the buttons of remote control.
Summary of Contents for DS 512
Page 1: ...Vehicle Security System GSM SMS Pager DS 512 CAN GSM GPS INSTALLATION MANUAL ver 0 14 ...
Page 16: ...16 tytan Diagram No 2 Mode 2 OEM VSS CAN Pager ...
Page 20: ...20 tytan Diagram No 6 connection of RF receiver module with analogue power door lock control ...
Page 21: ...Digital Systems 21 Diagram No 7 connection of second additional sensor with pre alarm ...