14
tytan
10. GIVING THE SYSTEM TO THE USER
After the system is installed and checked, the user must be informed about operation of the
system, the meaning of VSS PIN code and obliged to change individual VSS PIN code,
mobile phone numbers, number of mobile phones and to test operation of at least status
or localisation SMS command. After that the SMS Paging must be tested.
11. TECHNICAL DATA
Power supply:
9-30V
Mean (300 seconds) power consumption at 12V :
16mA
Maximum sink current per single output:
500mA
Temperature range:
from -
40°C to +85°C
Alarming time:
30 sec.
12. DESCRIPTION OF INPUTS/OUTPUTS
Name
Active signal
Function
1
CANH
Vehicle CAN-bus connection required to read information on
OEM remote, door status, ignition status and CAN-bus
vehicle control.
2
CANL
3
STATUS1-
other VSS armed
input / ground
Modes 2, 3, 4:
analogue signal required to distinguish OEM remote signal in
some vehicles (e.g. Renault Clio).
Mode 1:
input of ground signal informing, that monitored VSS is
armed.
4
Alarm triggering
input (Bonnet)
Alarm sensing input
(pager)
Input / configurable:
Ground or positive,
NO or NC
Modes 2, 3, 4: Bonnet switch input, triggering alarm if in
armed mode.
Mode 1: Alarming detection input in pager mode, reacts on
signal longer than 1s.
5
PA button /
additional sensors
input
Other VSS input
monitoring
Input /
Ground
Modes 2,3,4: PA button input. Additional sensors input.
Mode 1: Monitoring other VSS analogue input signals.
6
Ignition
Input /
Positive
Modes 1,2,3,4 analogue ignition signal input.
Modes 2,3,4, - on some vehicles,
which do have
icon in installation diagram
analogue signal
required to distinguish information on OEM remote in some
vehicles (e.g. Mazda 3, Subaru Forester).
7
Power supply
DS512 power supply 9-30V
8
Ground when
Armed
Output
Line switched to ground when the DS512 is armed in modes
3 and 4 (stand alone VSS system). The line gives power
supply for additional sensors.
9
Not used
10
LED
Output /
Ground (1.5A)
Switched ground control of LED. In DS512 cable loom, there
is the resistor that limits the LED current.
11
Hazard lights
Output /
Ground (1.5A)
Perimeter hazard lights control (hazard lights switch
connection) or hazard lights relays control signal (blinking)
for high-current bulb circuit connection.
12
Immobilisation relay
Output /
Ground (1.5A)
Switched ground control of immobilisation NC relay. The
relay is activated when the alarming starts The relay is
deactivated when the VSS is disarmed.
13
Siren
Output /
Ground (1.5A)
Switched ground control of electronic siren.
14
Ground
DS512 ground
Summary of Contents for DS 512
Page 1: ...Vehicle Security System GSM SMS Pager DS 512 CAN GSM GPS INSTALLATION MANUAL ver 0 14 ...
Page 16: ...16 tytan Diagram No 2 Mode 2 OEM VSS CAN Pager ...
Page 20: ...20 tytan Diagram No 6 connection of RF receiver module with analogue power door lock control ...
Page 21: ...Digital Systems 21 Diagram No 7 connection of second additional sensor with pre alarm ...