background image

-20-

Enable/Disable Download Data with Machine ID

Each BCP unit comes with a unique Machine ID (an eight-digit
number) from factory. The Machine ID is stored inside the
firmware and cannot be modified without removing the IC.
This menu item allows you to include/exclude the Machine ID
to be displayed in the output window of the download
operation for identification purpose. This option is useful when
multiple BCP units are being used to collectively capture
barcode data.

Note that Machine ID tagging with real-time data (tethered
scanning) is associated with each single record; whereas
Machine ID tagging with batch data (downloaded from BCP
memory) pertains to the entire data file. Refer to the Hyper
Terminal example in Section 4.2.2 and the Download Data
example in Section 4.2.4 for comparison.

Summary of Contents for BCP-1100

Page 1: ...BCP 1100 BCP 4100 Portable Memory Barcode Scanner User s Manual...

Page 2: ...9 3 3 3 Low Battery Warning Double Beep 9 3 3 4 Low Memory Warning Green LED Triple Beep 9 3 3 5 Memory Full Warning Red LED Continuous Beep 9 3 4 Real Time Clock RTC 10 4 Operation Guide 11 4 1 Logi...

Page 3: ...list is for reference only Due to different options the contents in the package may be different If any of the items are damaged or missing please contact your supplier immediately Please keep the pac...

Page 4: ...ode 39 Full ASCII Code 39 UPC EAN JAN Codabar Interleaved 2 5 Code 11 Code 93 MSI Plessey Code 128 RSS 14 optional Housing ABS Color Black Weight 100g Operating Temperature 0 C to 45 C Storage Tempera...

Page 5: ...r RS 232 to BCP 3 For USB interface connect the USB A male end of the cable to a free USB port on your system For RS 232 interface connect the DB9F end of the cable to a free serial port on your syste...

Page 6: ...d data at this point in order to resume your operation 3 2 Utility and USB Driver Installation 3 3 LED Status Indicator There are two subfolders on the utility driver CD BCP Utility and USB Driver Run...

Page 7: ...ed at factory You need to set it up when you use the unit the first time and each time you install a new battery 4 Operation Guide 4 1 Login Upon startup of the BCP utility you will be prompted to log...

Page 8: ...o log in to the scanner again 4 2 Main Menu Upon successful login you are presented with the main menu containing 4 submenus File Setting Transmit and Download 4 2 1 File File menu contains 4 items De...

Page 9: ...on Select this option to set Buzzer pitch and Duration The higher the value the higher the pitch and longer the duration will be Barcode General Parameter Select this option to enable disable prefixin...

Page 10: ...arcode after another without any delay as long as they are different 4 2 3 Transmit When you are done with all your changes you must select Transmit and click the Transmit button to transfer the new s...

Page 11: ...Confirm New Password field Enable Disable Real Time Clock Disable Enable The date and time of a successful scan are logged in the BCP unit This menu item allows you to include exclude the timestamp to...

Page 12: ...in the output window of the download operation for identification purpose This option is useful when multiple BCP units are being used to collectively capture barcode data Note that Machine ID taggin...