Tyco Kendall Kangaroo Joey Operating And Service Manual Download Page 1

kENDALL

KANGAROO JOEY

Enteral Feeding Pump

Enteral Feeding Pump — Operation and Service Manual

Nutripompe — Manuel d’utilisation et d’entretien

Pumpe für die enterale Ernährung — Benutzer- und Service-Handbuch

Pompa di alimentazione enterale — Manuale operativo e di manutenzione

Bomba para alimentación enteral — Manual de operación y servicio

Enteral matningspump — Användar- och servicemanual

Enterale voedingspomp — Gebruiks- en onderhoudshandleiding 

Bomba de alimentação entérica — Manual de funcionamento e assistência

Enteraalinen ravitsemuspumppu — Käyttö- ja huolto-opas

Pumpe til enteral ernæring — Betjenings- og servicehåndbog

Aντλία εντερικής σίτισης — Εγχειρίδιο λειτουργίας και συντήρησης

Pumpa pro enterální výživu — Provozní a servisní příručka

Enterális táplálópumpa — Kezelési és karbantartási kézikönyv

Насос для энтерального питания — Руководство по эксплуатации и техническому обслуживанию

Pompa żywienia dojelitowego — Instrukcja obsługi i serwisowania

Enteral Besleme Pompası — Kullanım ve Servis Kılavuzu

Enteral ernæringspumpe — Bruker- og vedlikeholdshåndbok

Operation and Service Manual

0123

Rx

ONLY

™

™ Trademark of Tyco Healthcare Group LP or its affiliate.

™*SPRAYNINE is a trademark of SprayNine Corporation.

™*PHISOHEX is a trademark of The Mentholatum Company.

™*HIBICLENS is a trademark of Regent Medical Limited.

™*VESTA-SYDE is a trademark of Steris Inc. 

  TYCO HEALTHCARE GROUP LP  •  15 HAMPSHIRE STREET  •  MANSFIELD, MA 02048  •  MADE IN U.S.A.  •  © 2008 TYCO HEALTHCARE GROUP LP

ALL RIGHTS RESERVED  •  080516  •  PRODUCT INFORMATION IN U.S. 1-800-962-9888  •  www.tycohealthcare.com
                    TYCO HEALTHCARE U.K. LTD  •  GOSPORT PO13 0AS, U.K. 

182545

Summary of Contents for Kendall Kangaroo Joey

Page 1: ...Pumpa pro enter ln v ivu Provozn a servisn p ru ka Enter lis t pl l pumpa Kezel si s karbantart si k zik nyv Pompa ywienia dojelitowego Instrukcja obs ugi i serwisowania Enteral Besleme Pompas Kullan...

Page 2: ...fication 4 Section IV Initial Setup Attaching the A C Adapter Power Cord 5 Battery Setup 6 Attaching Pole Clamp 6 SectionV Instructions for Use Quick Start 7 General Startup 8 Placement Mounting 8 A C...

Page 3: ...Flushing 16 Run 17 KTO 18 Lock Screen Feature 18 Hold 19 Flush Now 20 More Options 20 Buzzer AlarmVolume 20 History 20 Language Selection 21 Continuous Intermittent Mode 21 BioTech Menu 21 Accessing...

Page 4: ...s 32 Symbols on Pump and Accessories 35 Section XI Customer Service 36 Section XII Maintenance Top Door Enclosing Pump Set Loading Area 36 Battery Pack 37 Battery Door 37 Power Cord 37 Pole Clamp 37 S...

Page 5: ...tTouch rubberized casing for easy grip and drop protection Quick Release pole clamp for easy detachment of pump Features MISTIC Magnetic Intelligent SetType Identification Connector Feed Only vs Feed...

Page 6: ...wer Easily removable power cord Figure 1A KANGAROO JOEY Enteral Feeding Pump features front and rear views Menu Selections Menu Selection Buttons Graphic Display Front Door Back Battery Door Serial I...

Page 7: ...see SectionVI Re certification of Performance For other integrity checks consult with a qualified Biomedical Technician or contact the manufacturer Section XI Customer Service 7 For service or for te...

Page 8: ...nd the pump rotor 15 Do not attempt to rotate the valve stem inside the feeding set valve assembly Rotation of the valve stem can only be done by the pump while the valve assembly is properly loaded i...

Page 9: ...of the pump See Figure 1A to locate port on pump NOTE It is important to make sure the power plug is pushed all the way into the pump for proper operation If the display screen shows the pump is runn...

Page 10: ...18 hours of service before needing to be recharged Attaching Pole Clamp The KANGAROO JOEY Enteral Feeding Pump can be attached to a vertical pole using the pole clamp which is included with the pump a...

Page 11: ...l 2 Open blue door enclosing pump set loading area 3 To load pump set refer to Figure 4 Grasp finger tab on valve and insert into front pocket 1 Grasp black ring retainer and wrap tubing around rotor...

Page 12: ...MORE options menu 8 Press4RUN when ready to start The screen will displayRUNNING 9 To stop press4HOLD or press and hold the POWER button 182541 6 in 15 2 cm 6 in 15 2 cm Figure 4B Correct Fluid Level...

Page 13: ...rough the MORE OPTIONS menu see Figure 10A Keep or Clear Prior Pump Settings Immediately after powering up the pump if the prior feed or flush settings were not cleared and the settings are not locked...

Page 14: ...ot on the left Figure 6A 3 Grasp the MISTIC retainer end black ring retainer and wrap the tubing counterclockwise around the rotor Avoid overstretching the silicone tubing Figure 6B 4 Carefully pull t...

Page 15: ...ethod using the hold to prime feature After a pump set has been loaded and the status line shows SETLOADED press4PRIME PUMP in the opening menu Figures 7A 7D to get one of the PRIMEPUMP menus shown in...

Page 16: ...alve and then press4HOLDTO PRIME FEED until the feeding fluid has reached past the valve and down to the stepped end connector If the feeding line is primed first subsequent priming of the flushing li...

Page 17: ...e may be selected through the Biotech Options button which may be accessed on the Biotech screen see page 22 The EZ Pump Mode setting will be stored in the machine pump memory and saved when the unit...

Page 18: ...ogram the volume from 1 to 3000 mL in increments of 1 mL Press4ENTER top button to exit the menu If the FEEDVTBD is set to zero the pump will run until the supply is exhausted NOTE When a FEEDVTBD is...

Page 19: ...rs from the ADJUSTBOLUS screen Figure 13A Press4BOLUS RATE in Figure 13A to define the rate of delivery Press the4buttons in Figure 13B to program the delivery rate from 1 to 400 in increments of 1 mL...

Page 20: ...the time interval between starts of bolus Intermittent Mode Feeding Bolus Max Not Available in EZ Pump Mode The BOLUS MAX option can be used to deliver a bolus at a high rate similar to gravity feedi...

Page 21: ...settings which exceed pump capabilities to deliver CAUTION The KANGAROO JOEY Enteral Feeding Pump flushes at a rate of 1960 mL hr 32 7 mL minute Use care when programming the flush volume so that it...

Page 22: ...utton will increment the KTO time by 5 minute increments up to 30 minutes see Figure 15B After 30 is reached each additional button press will increment in larger time steps up to a maximum of240minut...

Page 23: ...return to one of the opening menus shown in Figures 7A 7D thus allowing any setting to be modified If the pump set has been removed after going into HOLD the opening menu will show LOADASET as seen i...

Page 24: ...USH NOW before the set volume has been delivered is desired press4FLUSH NOW and enter a volume of zero and press4ENTER The FLUSH NOW will stop immediately and the pump will return to the RUNNING mode...

Page 25: ...nformation Press4DONE in the MORE OPTIONS menu to exit the menu BioTech Menu The BioTech screen will show technical information about the pump and has a lock feature to lock the Pump Settings against...

Page 26: ...d again by pressing4LOCK SETTINGS to remove the check mark If the settings are locked and a change is attempted the screen will indicate PROGRAM LOCKED and will not allow access to the parameters Figu...

Page 27: ...of the water column is 6 inches above the pump Figure 4B Make sure pump is plugged into A C power do not run test with battery power Program a Continuous Mode feed rate see below for suggested example...

Page 28: ...power source before cleaning After cleaning do not connect to AC power source until pump and power cord are thoroughly dry A mild detergent should be used for general cleaning If necessary the pump ma...

Page 29: ...Representative or call Customer Service for instruction Section VIII Battery Replacement See Figure 24 and do the following to replace the Battery Pack Power down the unit Loosen the two battery door...

Page 30: ...AROO JOEY Enteral Feeding Pump display will show the error indicator icon with specific information regarding the error condition and will sound the alarm The following conditions will trigger error c...

Page 31: ...otor current 5 Never got a ADC ISR for battery level 6 Never got a ADC ISR for battery temperature 7 Never got a ADC ISR for Ultrasonic Upstream Occlusion or Bag Empty checks 8 Never got a ADC ISR for...

Page 32: ...ROTOR ERROR screen appears during RUNNING or PRIMING when the pump has detected an unusual operating condition for the rotor See Figure 27 The ROTOR ERROR generally results from a problem with the pu...

Page 33: ...ient Check the line to find the occlusion causing the blockage If the error cannot be resolved check the valve pocket in the pump set loading area for dampness or dirt which may be a cause for a false...

Page 34: ...n so it is flush with the back of the pump Figure 32 Battery Low error screen Indicates that the battery must be recharged immediately Feeding Complete Adjustable Audible Volume The FEEDING COMPLETE i...

Page 35: ...status especially in darkened rooms A green light status indicates normal pump operation A yellow light status indicates an informational or warning situation for a low battery condition the pump in H...

Page 36: ...f Boluses 1 99 Bolus Interval 1 24 hours in 1 hour increments Flushing Solution Dose Range 10 500 mL in 1 mL increments Flushing Solution Interval Range 1 24 hr in 1 hr increments Accuracy 7 or 0 5 mL...

Page 37: ...er cord NominalVoltage 3 7V DC Max Current 1800 A Battery New fully charged Lithium Ion Battery Pack delivers 18 hrs at 125 mL hr feed rate Approximately 15 minutes prior to complete battery discharge...

Page 38: ...75 R H non condensing StorageTemperature 0 50 C 32 122 F 95 R H non condensing Type of Protection Against Electrical Shock Class II Internally powered Equipment Degree of Protection Against Electrica...

Page 39: ...luids CE Mark European Community Certification Power Button Buttons for Selecting Screen Prompts Power Source 5VDC 2 4 A Caution For indoor use only Functional Ground Do not use KANGAROO JOEY Enteral...

Page 40: ...care Group LP Tyco Healthcare Canada 98 6 Faichney Drive 7300Trans Canadian Highway Watertown NY 13601 Pointe Claire QC H9R 1C7 1 800 448 0190 or 315 788 5246 1 877 664 8926 or 514 695 1220 U K Servic...

Page 41: ...ed several times to restore optimal capacity Battery Door To replace Battery Door see Figure 36 and do the following 1 Place Battery Door over battery opening Make sure the rubber periphery seal on th...

Page 42: ...ding Pump 383400 2 Main Door Blue transparent door Main Door Blue transparent door F32061 3 Battery Pack Battery Pack F010506 4 Battery Door Battery Door F31929 Power Cord with A C Adapter Power Cord...

Page 43: ...he defective part or product with a comparable part or product repair the defective part or product or if neither replacement nor repair is reasonably available refund to Customer the purchase price f...

Page 44: ...4 3 2002 Complies Conducted Disturbance Immunity EN60601 1 2 IEC 61000 4 6 2001 Complies Power Frequency Magnetic Field Immunity EN60601 1 2 IEC 61000 4 8 2001 Complies Voltage dips and sags Immunity...

Page 45: ...manufacturing process The KANGAROO ePump AccuSystem feeding set manufacturing process parameters are tightly controlled atTyco Healthcare Group LP to minimize variation and produce consistent and rel...

Page 46: ...sted per the pump s internal re certification protocol with the following results ManualTests Passed Failed BuzzerTest LEDTest BatteryTest MISTICTest AutoTest Inspector Name Signature Facility Address...