http://www.tyan.com
25
SlimSAS3: Vertical Slim SAS Connector
Signal Name
Pin
Pin
Signal Name
GND
A1
B1 GND
CPU1_PE2_ABCD_RX_DN8
A2
B2 CPU1_PE2_ABCD_TX_DP8_C
CPU1_PE2_ABCD_RX_DP8
A3
B3 CPU1_PE2_ABCD_TX_DN8_C
GND
A4
B4 GND
CPU1_PE2_ABCD_RX_DN9
A5
B5 CPU1_PE2_ABCD_TX_DP9_C
CPU1_PE2_ABCD_RX_DP9
A6
B6 CPU1_PE2_ABCD_TX_DN9_C
GND
A7
B7 GND
BP_TYPEC
A8
B8 PE_HD2_SMB_CLK
PE_WAKE_N2
A9
B9 PE_HD2_SMB_DAT
GND
A10 B10 GND
SLIMSAS_NVME2_DP
A11 B11 PCIE_SLIMSAS_RST_N
SLIMSAS_NVME2_DN
A12 B12 CPRSNTA-
GND
A13 B13 GND
CPU1_PE2_ABCD_RX_DN10 A14 B14 CPU1_PE2_ABCD_TX_DP10_C
CPU1_PE2_ABCD_RX_DP10 A15 B15 CPU1_PE2_ABCD_TX_DN10_C
GND
A16 B16 GND
CPU1_PE2_ABCD_RX_DN11 A17 B17 CPU1_PE2_ABCD_TX_DP11_C
CPU1_PE2_ABCD_RX_DP11 A18 B18 CPU1_PE2_ABCD_TX_DN11_C
GND
A19 B19 GND
SlimSAS4: Vertical Slim SAS Connector
Signal Name
Pin
Pin
Signal Name
GND
A1
B1 GND
CPU1_PE2_ABCD_RX_DN12
A2
B2 CPU1_PE2_ABCD_TX_DP12_C
CPU1_PE2_ABCD_RX_DP12
A3
B3 CPU1_PE2_ABCD_TX_DN12_C
GND
A4
B4 GND
CPU1_PE2_ABCD_RX_DN13
A5
B5 CPU1_PE2_ABCD_TX_DP13_C
CPU1_PE2_ABCD_RX_DP13
A6
B6 CPU1_PE2_ABCD_TX_DN13_C
GND
A7
B7 GND
BP_TYPED
A8
B8 PE_HD3_SMB_CLK
PE_WAKE_N3
A9
B9 PE_HD3_SMB_DAT
GND
A10 B10 GND
SLIMSAS_NVME3_DP
A11 B11 PCIE_SLIMSAS_RST_N
SLIMSAS_NVME3_DN
A12 B12 CPRSNTA-
GND
A13 B13 GND
CPU1_PE2_ABCD_RX_DN14 A14 B14 CPU1_PE2_ABCD_TX_DP14_C
CPU1_PE2_ABCD_RX_DP14 A15 B15 CPU1_PE2_ABCD_TX_DN14_C
GND
A16 B16 GND
CPU1_PE2_ABCD_RX_DN15 A17 B17 CPU1_PE2_ABCD_TX_DP15_C
CPU1_PE2_ABCD_RX_DP15 A18 B18 CPU1_PE2_ABCD_TX_DN15_C
GND
A19 B19 GND
Summary of Contents for S7126
Page 2: ...http www tyan com 2...
Page 8: ...http www tyan com 8 NOTE...
Page 11: ...http www tyan com 11 2 2 Block Diagram S7126 Block Diagram...
Page 12: ...http www tyan com 12 2 3 Mainboard Mechanical Drawing...
Page 34: ...http www tyan com 34...
Page 40: ...http www tyan com 40 DIMM Location...
Page 79: ...http www tyan com 79 Numa Enable or Disable Non uniform Memory Access NUMA Disabled Enabled...
Page 83: ...http www tyan com 83 3 3 9 3 1 1 UPI Status Read only...
Page 96: ...http www tyan com 96 3 3 9 5 4 Intel VMD Technology...
Page 98: ...http www tyan com 98 VMD Config for IOU4 Enable Disable VMD in this Stack Disabled Enabled...
Page 104: ...http www tyan com 104 Perf P Limit Enable Disable Performance P Limit Disabled Enabled...
Page 109: ...http www tyan com 109 3 3 10 Memory Topology Read only...
Page 120: ...http www tyan com 120 Max Payload Size PCIE Max Payload Size Selection MPL128B MPL256B...
Page 131: ...http www tyan com 131 NMI Button Enable or Disable NMI button Enabled Disabled...
Page 208: ...http www tyan com 208 BIOS Temp Sensor Name Explanation...
Page 209: ...http www tyan com 209...
Page 212: ...http www tyan com 212 NOTE...
Page 215: ...http www tyan com 215 4 The installation of the M 2 latch is now complete...
Page 216: ...http www tyan com 216 NOTE...