OPERATING INSTRUCTIONS
Gas Leak Test
Open flame should not be used in the area around the Infrared Sear Station during this test.
This procedure should be carried out each time the gas connection is disconnected.
1. Ensure that the burner knob is in the OFF position.
2. Open the burner knob slowly. Apply heavy soapy water or similar solution to all
connections including those made at the factory.
3. Inspect all connections for presence of bubbles. If bubbles appear, close shut-off valve
and tighten connections. Repeat steps 1 and 2 above until bubbles cease.
Lighting Instructions
1. Remove the cover from the Infrared Sear Station.
2. Ensure the Gas Supply Cylinder Valve is closed and the burner knob is set to the off
position.
3. Ensure that the grease tray is completely installed.
4. Open the valve on the gas supply cylinder.
5. Press in and rotate the burner knob counterclockwise to the “HI” position.
6. Press in and hold the ignition button. You should here a continuous clicking sound
indicating that a spark is being provided to the burner. (If clicking sound is weak, replace
battery.)
7. If ignition does not take place within 4 seconds, turn the burner knob to the off position,
leave the cover off, and wait 5 minutes to repeat lighting procedure.
8.
CAUTION: Do not leave the Infrared Sear Station unattended while cooking.
Manual Lighting Instructions
If the electronic ignition does not light the burner, the burner can be lit manually using a long
match (or taper).
1. Remove the cover from the Infrared Sear Station.
2. Ensure the Gas Supply Cylinder Valve is closed and the burner knob is set to the off
position.
3. Ensure that the grease tray is completely installed.
4. Remove the grates from the Infrared Searing Station.
5. Place a lit match (or taper) over the burner near the igniter.
6. Press in and rotate the burner knob counterclockwise slowly to the “HI” setting. Make
sure match (or taper) is lit before turning the knob.
7. If ignition does not take place within 4 seconds, turn the burner knob to the off position,
leave the cover off, and wait 5 minutes to repeat lighting procedure.
8.
CAUTION: Do not leave the Infrared Sear Station unattended while cooking.
Replacing the Battery
1. Unscrew the ignition button and remove the old battery.
2. Replace with a new 1.5 Volt AAA battery.
Extinguishing the Burner Flame
1. Depress and rotate burner knob to OFF.
2. Natural Gas: Turn the gas off at the installer supplied gas shut-off valve.
3. Liquid Propane: Close the valve on the gas supply cylinder.
10