TVU MLink Set-up and Operating Guide
TVU MLink
Page 70 of 75
Figure 69
For additional assistance, please contact TVU Support:
Phone: +1.650.440.4812
Email:
Skype: skype.tvupack
A
PPENDIX
B:
TVU
R
ECEIVER
TR
3750
The TVU Transceiver is the companion decoder for all TVU transmitters and helps
broadcasters monitor all aspects of a live transmission, including bit-rate and latency. The
TR3750 model is slightly different from other TVU Transceivers because it allows for two
TVU transmitters to be live simultaneously on one transceiver with two independent SDI
outputs and two separate TVU Receiver applications.
Additionally, it has a redundant power supply. it has a redundant power supply. Thus, if
the one power supply fails
(A)
(Figure 71), the other power supply
(B)
will keep running in
order to keep the TVU Transceiver powered up.
In order to use the dual power supplies properly, both AC power supplies must be plugged
into both of the AC power adapters on the back panel of the TR3750
(A)(B)
(Figure 71).
When one power supply fails, the TVU Transceiver will make a continuous beeping sound
to alert users of the failure.
Because of the dual outputs, the TR3750 requires some additional set-up. Normally, users
would only attach one SDI cable to the one SDI output on the transceiver unit
(G)
(Figure
71). However, this unit has a second SDI output
(I)
on the back connections panel as seen
in Figure 71. In order to access the second SDI output, simply plug an additional SDI cable
Summary of Contents for MLink TE4100