TVU MLink Set-up and Operating Guide
TVU MLink
Page 24 of 75
Preset
Frequency (MHz) Modulation
Guard FEC
Ch1
2031.500
QPSK
1/8
1/2
Ch2
2043.500
QPSK
1/8
½
Ch3
2052.500
QPSK
1/8
½
Ch4
2067.500
QPSK
1/8
½
Ch5
2079.500
QPSK
1/8
½
Ch6
2088.500
QPSK
1/8
½
Ch7
2103.500
QPSK
1/8
½
Ch8
2458.500
QPSK
1/8
½
Ch9
2475.250
QPSK
1/8
½
Ch10
2492.000
QPSK
1/8
1/2
Figure 22
After selecting a Preset and pressing “Apply”, that will be the current preset and persist
across reboots
(C)
(Figure 23).
Note
: All frequencies are expressed to three decimal points.
There are also six user definable presets available. With the user definable presets that
are numbered Channel 11-16, it is possible for the user to set and save a custom preset
settings. Definable settings options are:
•
Frequency:
Any frequency between 2000.000 MHz and 2700.000MHz
•
DVB-T COFDM Bandwidth
: 6, 7, or 8MHz
•
Modulation
: QPSK, 16QAM, 64QAM
•
FEC
: ½, 2/3, ¾, 5/6, 7/8
•
Guard Interval
: ¼, 1/8, 1/16, 1/32
•
Power
: Hi or Low
To create a custom preset, select channel 11-16 and select the desired settings. Press
“Add” to add this new custom frequency to the available Presets
(L)
(Figure 23). A custom
preset can be changed at anytime by making a change to the preset’s settings and
pressing “Add”. Custom frequencies are available in the “Load Preset” drop down menu
(E).
Summary of Contents for MLink TE4100