Following options are provided:
Disable
Low
Mid 1
Mid 2
Mid 3
High
Operation and response is similar to the above case.
5.2.9. Factory Settings
Recommended, factory default levels, for proper operation and response to
convert normal quality signals is:
Luma
AGC:
Enabled
Chroma
AGC:
Enabled
Low Pass Filter: Highest for the standard
U
(B-Y)
Gain:
0
U
(B-Y)
Offset:
0
V
(R-Y)
Gain:
0
V
(R-Y)
Offset:
0
CTI:
Disabled
Noise
Reduction:
Disabled
6.0 TROUBLESHOOTING
Other than checking for faulty cables, the other common problem would be
operating with a wrong standard. Make sure the selected input standard and
format match the input connections.
After trying the above suggestions should the problem still persist, contact your
dealer for additional suggestions before contacting TV One. Should the dealer’s
technical personnel be unable to assist you, contact TV One via our support
website:
http://tvone.crmdesk.com.
Create a technical support request on the
site and our support team will respond within a short period of time.