4.9
Basic settings
In the Basic settings menu, all basic parameters for the controller can be adjusted.
Normally, these settings have been made during commissioning. They can be subse-
quently changed in this menu.
Adjustment chan-
nel
Description
Adjustment range / se-
lection
Factory setting
Language
Selection of the menu language
Deutsch, English,
Français, Español, Italiano
Deutsch
Auto DST
Daylight savings time selection Yes, No
Yes
Date
Adjustment of the date
01.01.2001 … 31.12.2099 01.01.2012
Time
Adjustment of the current time 00:00 … 23:59
-
Targ. temp.
Target temperature control
30 … 70 °C
60 °C
Reset
back to factory setting
Yes, No
No
4.10 MicroSD card
SD card
Adjustment channel Description
Adjustment range / selection Factory setting
Rem. time
Remaining logging time -
-
Options
Remove card...
Safely remove card
-
-
Save adjustments
Save adjustments
-
-
Load adjustments
Load adjustments
-
-
Logging int.
Interval for data logging 00:01 … 20:00 (mm:ss)
01:00
Logging type
Logging type
Cyclic, Linear
Linear
The controller is equipped with a MicroSD card slot for MicroSD memory cards.
With a MicroSD card, the following functions can be carried out:
• Logging measurement and balance values. After the transfer to a computer, the
values can be opened and visualised, e.g. in a spreadsheet.
• Store adjustments and parameterisations on the MicroSD card and, if necessary,
retrieve them from there.
• Running firmware updates on the controller.
Firmware updates
When a MicroSD card with a firmware update is inserted, the enquiry Update? is
indicated on the display.
Î
In order to run an update, select Yes and confirm with the right button (
✓
).
The update will run automatically. The indication Please wait... and a progression
bar will appear on the display. When the update has been completed, the controller
will automatically reboot and run a short initialisation phase.
Note:
Only remove the card when the initialisation phase has been completed
and the main menu is indicated on the controller display!
Î
To skip the update, select No.
The controller starts normal operation.