PROGRAM SET UP
It will be operated with the default value of the essential user settings when it is
connected to a DC 11~30V batttery for the first time.The screen displays the following
information in sequence and the user can change the value of parameter on each screen.
When you are willing to alter the parameter value in the program, press Start/Enter key to
make it blink then change the value with INC or DEC key. The value will be stored by
pressing Start/Enter key once.
PROGRAM SELECT
SYSTEM SET
Rest Time
CHG
>
DCHG 10Min
SAFETY TIME
ON 120Min
INC
DEC INC
DEC INC
DEC INC
DEC INC
Capacity Cut-Off
ON 5000mAH
DEC INC
DEC INC
DEC INC
DEC INC
Key Beep ON
Buzzer ON
DEC INC
D E C
I NC
The battery is on the cyclic process of charge and discharge can
often become warm after charge or discharge period. The program
can insert a time delay to occur after each charge and discharge
process to allow the battery adequate time to cool down before
being subjected to the next process. The value ranges from 1 to 60
minutes.
When you start a charge process, the integral safety timer
automatically starts running at the same time. This is programmed
to prevent overcharge the battery if it proves to be faulty, or if the
termination circuit cannot detect the battery full. The value for the
safety timer should be generous enough to allow a full charge of
the battery.
Safe timer Calculation
When charging NiCd or NiMH batteries, divide the capacity by
current, then divide the result by 11.9, set this number as the value
for safety timer setting. If the charger stopped at this threshold,
about 140% of the capacity will have been fed into the battery.
User set up starting screen.
This program sets the maximum charge capacity that will be
supplied to the battery during charge. If the deltapack voltage is not
detected nor the safety timer expired by any reason, this feature
will automatically stop the process at the selected capacity value.
The beep sounds at every time pressing the buttons to confirm
your action. The beep or melody sounded at various times during
operation to alert different mode changes.
These audible sounds can be on or off.
Capacity
Current
Safety Time
2000mAh
2.0A
(2000/2.0=1000)/11.9=84 minutes
3300mAh
3.0A
(3300/3.0=1100)/11.9=92 minutes
1000mAh
1.2A
(1000/1.2=833)/11.9=70 minutes
For example:
Turnigy Mega 1000W