09

PROGRAM FLOW CHART  

PROGRAM SELECT
      BATT MEMORY

ENTER

START

BATT MEMORY [1]
ENTER SET

ENTER

START

BATT TYPE
LiPo

DEC

INC

BATT VOLTS
       7.4V ( 2S )

DEC

INC

CHARGE CURRENT
                           4.9A

DEC

INC

DSCH CURRENT
                           2.2A

DSCH VOLTAGE
                 3.0V/CELL

TVC=YOUR RISK
                         4.20V

DEC

INC

ENTER

START

ENTER

START

PROGRAM SELECT
      SYSTEM SET->

Rest Time
CHG>DCHG    10Min

VERSION
                            1.00

ENTER

START

DEC

INC

SAFETY TIME
ON                  120Min

DEC

INC

Capacity Cut-Off
ON             5000mAH

DEC

INC

Key Beep             ON
Buzzer                 ON

DEC

INC

Input Power Low
Cut-Off              11.0V

Ext. Temp              0C
Int. Temp              37C

DEC

INC

LOAD FACTORY SET
                       ENTER

DEC

INC

Stop

Batt Type

DEC

INC

SAVE PROGRAM 
                      ENTER

SAVE PROGRAM 
SAVE….

BATT MEMORY [1]
LiPo  7.4V (2S )

ENTER

START

BATT MEMORY [1]
C:4.9A  D:2.2A

ENTER CHARGER
LOAD……

LiPo BALANCE
4.9A      7.4V(2S)

DEC

INC

LiPo CHARGE
4.9A      7.4V(2S)

DEC

INC

LiPo FAST CHG
4.9A      7.4V(2S)

DEC

INC

LiPo STORAGE 
4.9A      7.4V(2S)

LiPo DISCHARGE
2.2A      7.4V(2S)

DEC

INC

DEC

INC

BATT MEMORY 2
NiMH   2.4V (2S)

BATT TYPE
MiMH

DEC

INC

BATT VOLTS

    

2.4V (2S)

ENTER

START

CHARGE CURRENT
                          3.3A

DEC

INC

DEC

INC

TRICKLE
              100mA

DEC

INC

PEAK DELAY
                         1Min

DEC

INC

DSCH CURRENT
                          2.2A

DEC

INC

DSCH VOLTAGE

    

1.1V/CELL

DEC

INC

DELTA PEAK SENSE

     

4Mv/C

SAVE PROGRAM 
ENTER

DEC

INC

BATT MEMORY 3
Pb   4V (2S)

ENTER

START

BATT TYPE
Pb

BATT VOLTS
                   4.0V (2S)

DEC

INC

CHARGE CURRENT
                          3.3A

DEC

INC

DSCH CURRENT

      

1.5A

DEC

INC

DSCH VOLTAGE

    

1.7V/CELL

DEC

INC

DEC

INC

SAVE PROGRAM 
ENTER

DEC

INC

PROGRAM SELECT
            Pb BATT 

ENTER

START

Pb CHARGE
2.0A     2.0V (1P)

DEC

INC

Pb DISCHARGE
0.1A     2.0V (1P)

DEC

INC

PROGRAM SELECT
          NiCD BATT

NiCD CHARGE
CURRENT     2.0A

ENTER

START

DEC

INC

NiCD DISCHARGE
0.1A       CUT: 1.0V

DEC

INC

NiCD CYCLE
CHG>DCHG     

   

  1

DEC

INC

PROGRAM SELECT
          NiMH BATT 

ENTER

START

NiMH CHARGE
CURRENT     2.0A

DEC

INC

NiMH DISCHARGE
0.1A       CUT: 1.0V

NiMH CYCLE
CHG>DCHG          1

DEC

INC

PROGRAM SELECT
           LiPo BATT

LiPo BALANCE
2.0A     7.4V (2S)

LiPo CHARGE
2.0A         7.4V (2S)

LiPo FAST CHG
2.0A     7.4V (2S)

LiPo STORAGE
2.0A     7.4V (2S)

LiPo DISCHARGE
2.0A         7.4V (2S)

ENTER

START

DEC

INC

DEC

INC

DEC

INC

DEC

INC

DEC

INC

DEC

INC

PROGRAM SELECT
           Lilo BATT

Lilo BALANCE
2.0A     7.2V (2S)

Lilo CHARGE
2.0A     7.2V (2S)

Lilo FAST CHG
2.0A    7.2V (2S)

Lilo STORAGE
2.0A    7.2V (2S)

Lilo DISCHARGE
2.0A     7.2V (2S)

ENTER

START

DEC

INC

DEC

INC

DEC

INC

DEC

INC

PROGRAM SELECT
           LiFe BATT

LiFe BALANCE
2.0A     6.6V (2S)

LiFe CHARGE
2.0A     6.6V (2S)

LiFe FAST CHG
2.0A    6.6V (2S)

LiFe STORAGE
2.0A    6.6V (2S)

LiFe DISCHARGE
2.0A     6.6V (2S)

ENTER

START

DEC

INC

DEC

INC

DEC

INC

DEC

INC

DEC

INC

ENTER

START

PROGRAM SELECT

 

Li   BATT METER

4.20   4.19    4.19 V
0.00   0.00    0.00 V

MAIN 0.00V  
H0.000V     L0.000V

DEC

INC

DEC

INC

DEC

INC

DEC

INC

DEC

INC

DEC

INC

NiCD RE-PEAK
                         1

DEC

INC

NiMH RE-PEAK
                         1

DEC

INC

NiMH Auto CHARGE
CURRENT     2.0A

DEC

INC

NiCD Auto CHARGE
CURRENT     2.0A

DEC

INC

TEMPERATURE
CUT-OFF          50C

DEC

INC

TEMPERATURE
CUT-OFF          50C

DEC

INC

DEC

INC

TEMPERATURE
CUT-OFF          50C

Turnigy Mega 1000W

0.00V        0.00V

DEC

INC

ENTER

START

ENTER

START

Summary of Contents for MEGA 1000W

Page 1: ...OPERATING MANUAL For LiPo LiFe LiIon NiMH NiCd Pb Batteries MEGA1000W MEGA1000W MEGA1000W MEGA1000W...

Page 2: ...ER CHART COMMONLY USED TERMS WARRANTY AND SERVICE Charging Lithium battery at balance mode Charging of Lithium Battery FAST charging of Lithium battery STORAGE control of lithium battery Discharging L...

Page 3: ...wner of a professional charger discharger with battery management and integral balancer gy Mega 1000W INTRODUCTION 02 Display Large 2x16 LCD for Easy Reading DC INPUT 11 30V Output Temperature Sensor...

Page 4: ...have many years of pleasure and success with your new battery charger Turnigy Mega 1000W employs the circuit that features output power of 1000 watts It can charge or discharge up 20 cells of NiCd NiM...

Page 5: ...of any single one cell is abnormal Special features SPECIAL FEATURES Adaptable to various type of lithium battery Turnigy Mega 1000W is adaptable to various types of lithium batteries such as Li Ion L...

Page 6: ...10 data of different batteries You can establish the data contains program setting of the battery to charge or discharge These data can be called back at any time you need and the process can be execu...

Page 7: ...ischarged to ensure it meets the requirements of this charger If the program is set up incorrectly the battery and charger may be damaged It can cause fire or explosion due to overcharging This warran...

Page 8: ...at any point in the circuit Charging During charge process a specific quantity of electrical energy is fed into the battery The charge quantity is calculated by multiplying charge current by charge t...

Page 9: ...NiCd and NiMH batteries are suffering from memory effect NiCd has more memory effect than NiMH Lithium batteries are recommended to be discharged partially rather than fully discharged Frequent full...

Page 10: ...7V CELL DEC INC DEC INC SAVEPROGRAM ENTER DEC INC PROGRAMSELECT PbBATT ENTER START PbCHARGE 2 0A 2 0V 1P DEC INC PbDISCHARGE 0 1A 2 0V 1P DEC INC PROGRAMSELECT NiCDBATT NiCDCHARGE CURRENT 2 0A ENTER...

Page 11: ...a 1000W comes with male 4mm Bullet connectors attached to the power INPUT cables These cables are appropriate for attaching directly to most high quality AC DC power supply units such as TURNIGY 1200W...

Page 12: ...harger To avoid short circuit between the charge lead always connect the charge cable to the charger first then connect the battery Reverse the sequence when disconnecting WARNING Balance socket The b...

Page 13: ...itor the voltages of each cell of the battery pack and controls charging current that is feeding to each cell to normalise the voltage Note We recommends charging lithium batteries with a balance lead...

Page 14: ...Type Stop key once to stop the charge process The value on the left side of the second lines sets the charge current The value on the right side of the second lines sets the battery pack s voltage Aft...

Page 15: ...real time status charging Press Batt Type Stop key once to stop the charge process This displays the number of cells you set up and the processor detects R shows the number of cells detected by the c...

Page 16: ...DEC Batt type Stop INC DEC Start Enter INC Battery type Elapsed time Discharge current Battery voltage Discharged capacity 3 seconds Set up the charge current on the left and the nominal voltage of th...

Page 17: ...ls applications You can press Start Enter key to make it blink and then Inc or Dec to change the parameter value Press START ENTER key to store the value Set discharge current on the left and final vo...

Page 18: ...RPC 000 33 00017 ENTER START Re peak cycle 1 shows on the display Press the Start Enter button to make the re peak cycle number blink and press the Dec Inc button to find the desired number of times...

Page 19: ...ger can store up to 10 different charge discharge profiles for your convenience and the stored profiles can be recalled quickly without having to go through the setup process BATT MEMORY 1 ENTER SET B...

Page 20: ...button for more than three seconds This screen indicate the saved profile Once you ve saved a charge profile you can load those settings to use later To load a memory you have to press the Start Ente...

Page 21: ...18V 0 00 0 00 0 00V MAIN 12 52V H4 190V L4 160V Start Enter INC Press the Start Enter button to enter the Lithium Battery Meter The screen indicate each cell s voltage The screen indicate the total v...

Page 22: ...ral safety timer automatically starts running at the same time This is programmed to prevent overcharge the battery if it proves to be faulty or if the termination circuit cannot detect the battery fu...

Page 23: ...oltage of input battery If the voltage drops below the value you set the operation forcibly terminated to protect the input battery Press and hold the Start Enter button for more than three seconds to...

Page 24: ...ection cable is linked to the Lithium battery being processed It comes to the final voltage when the program ended Present input voltage Displayed safety timer is turn on and duration of time in minut...

Page 25: ...low CELL error Low Voltage The internal temperature of the unit goes too high Int temp too hi DC in too low Input voltage less than 11V Input voltage higher than 30V DC in too high BATTERY WAS FULL Th...

Page 26: ...Po Ion Fe Li ion Fe Polymer cell count NiCd NiMH battery cell count Pb battery voltage Net weight Dimension DC 11 0 30 0 Volt Max Charge power 1000Watts Max Discharge power 40Watts 0 1 40 0A 0 1 8 0A...

Page 27: ...ximum circuit power chart Output 1 2 Per Output 5 0 3 0 2 0 1 5 1 2 1 0 5 0 3 0 2 0 1 5 1 2 1 0 5 0 3 5 2 3 1 7 1 4 1 2 5 0 5 0 4 2 3 3 2 8 2 4 2 1 1 9 1 7 1 5 1 4 1 3 1 2 1 1 20 0 20 0 20 0 20 0 19 0...

Page 28: ...quantity of charge 2 Ah if it is charged for 4 hours at 0 5 A or 15 minutes 1 4 h at 8 A C rating Capacity is also referred to as the C rating Some battery suppliers recommend charge and discharge cur...

Page 29: ...clusively for use with the types of battery stated in this Instruction Manual Hextronik accepts no liability of any kind if the charger is used for any purpose other than that stated We are unable to...