background image

14 ·

 LITHIUM BATTERY(LIPO/LILO/LIFE)PROGRAM

 'STORAGE' control of lithium battery

This is for charging or discharging Lithium battery not to be used for the time being. The 
program  will  determine  to  charge  or  discharge  the  battery  to  the  certain  voltage 
depending on the voltage of the battery at its initial stage. They are different from the type 
of  the  battery,  3.75V  for  LiIo,  3.85V  for  LiPo  and  3.3V  for  LiFe  per  cell.  If  the  voltage  of 
battery  at  its  initial  stage  is  over  the  voltage  level  to  storage,  the  program  will  start  to 
discharge.

Number
of
cells

DEC

- +

Batt type
   Stop

Elapsed
time

INC

Charge 
or discharge
current

Supplied
capacity

DEC

Start
Enter

-

INC

+

Current
voltage
battery

'> 3 seconds  '

Start
Enter

Number
of
cells

DEC

-

Batt type
   Stop

elapsed
time

INC

+

Battery
voltage

DEC

Start
Enter

-

INC

+

Discharged
capacity

discharge
 current

'> 3 seconds  '

Start
Enter

Discharging Lithium battery

At this screen, you can set up the current and voltage of the battery 
pack. Charging and discharging will make the batteries come to the 
voltage level of storage state.

This  screen  shows  the  real-time  status  charging.  Press  Batt 
Type/Stop key once to stop the charge process.

This  displays  the  number  of  cells  you  set  up  and  the  processor 
detects.  R shows the number of cells detected by the charger and 
S is the number of cells set by you at the previous screen. If both 
numbers  are  identical  you  can  start  charging  by  press  Start/Enter 
button.  If  not,  press  Batt  Type/Stop  button  to  go  back  to  previous 
screen  to  carefully  check  the  number  of  cells  of  the  battery  pack 
before going ahead.

The value of discharge current on the left can not exceed 1C, and 
the value on the right can not be under the voltage recommended 
by  the  manufacturer  to  avoid  deep  discharging.  Press  Start/Enter 
for more than 3 seconds to start discharging.

This shows the real-time status of discharging, you can press Batt 
Type/Stop key to stop discharging.

This  displays  the  number  of  cells  you  set  up  and  the  processor 
detects.  R shows the number of cells detected by the charger and 
S is the number of cells set by you at the previous screen. If both 
numbers  are  identical  you  can  start  charging  by  press  Start/Enter 
button.  If  not,  press  Batt  Type/Stop  button  to  go  back  to  previous 
screen  to  carefully  check  the  number  of  cells  of  the  battery  pack 
before going ahead.

Turnigy Mega 1000W

Summary of Contents for MEGA 1000W

Page 1: ...OPERATING MANUAL For LiPo LiFe LiIon NiMH NiCd Pb Batteries MEGA1000W MEGA1000W MEGA1000W MEGA1000W...

Page 2: ...ER CHART COMMONLY USED TERMS WARRANTY AND SERVICE Charging Lithium battery at balance mode Charging of Lithium Battery FAST charging of Lithium battery STORAGE control of lithium battery Discharging L...

Page 3: ...wner of a professional charger discharger with battery management and integral balancer gy Mega 1000W INTRODUCTION 02 Display Large 2x16 LCD for Easy Reading DC INPUT 11 30V Output Temperature Sensor...

Page 4: ...have many years of pleasure and success with your new battery charger Turnigy Mega 1000W employs the circuit that features output power of 1000 watts It can charge or discharge up 20 cells of NiCd NiM...

Page 5: ...of any single one cell is abnormal Special features SPECIAL FEATURES Adaptable to various type of lithium battery Turnigy Mega 1000W is adaptable to various types of lithium batteries such as Li Ion L...

Page 6: ...10 data of different batteries You can establish the data contains program setting of the battery to charge or discharge These data can be called back at any time you need and the process can be execu...

Page 7: ...ischarged to ensure it meets the requirements of this charger If the program is set up incorrectly the battery and charger may be damaged It can cause fire or explosion due to overcharging This warran...

Page 8: ...at any point in the circuit Charging During charge process a specific quantity of electrical energy is fed into the battery The charge quantity is calculated by multiplying charge current by charge t...

Page 9: ...NiCd and NiMH batteries are suffering from memory effect NiCd has more memory effect than NiMH Lithium batteries are recommended to be discharged partially rather than fully discharged Frequent full...

Page 10: ...7V CELL DEC INC DEC INC SAVEPROGRAM ENTER DEC INC PROGRAMSELECT PbBATT ENTER START PbCHARGE 2 0A 2 0V 1P DEC INC PbDISCHARGE 0 1A 2 0V 1P DEC INC PROGRAMSELECT NiCDBATT NiCDCHARGE CURRENT 2 0A ENTER...

Page 11: ...a 1000W comes with male 4mm Bullet connectors attached to the power INPUT cables These cables are appropriate for attaching directly to most high quality AC DC power supply units such as TURNIGY 1200W...

Page 12: ...harger To avoid short circuit between the charge lead always connect the charge cable to the charger first then connect the battery Reverse the sequence when disconnecting WARNING Balance socket The b...

Page 13: ...itor the voltages of each cell of the battery pack and controls charging current that is feeding to each cell to normalise the voltage Note We recommends charging lithium batteries with a balance lead...

Page 14: ...Type Stop key once to stop the charge process The value on the left side of the second lines sets the charge current The value on the right side of the second lines sets the battery pack s voltage Aft...

Page 15: ...real time status charging Press Batt Type Stop key once to stop the charge process This displays the number of cells you set up and the processor detects R shows the number of cells detected by the c...

Page 16: ...DEC Batt type Stop INC DEC Start Enter INC Battery type Elapsed time Discharge current Battery voltage Discharged capacity 3 seconds Set up the charge current on the left and the nominal voltage of th...

Page 17: ...ls applications You can press Start Enter key to make it blink and then Inc or Dec to change the parameter value Press START ENTER key to store the value Set discharge current on the left and final vo...

Page 18: ...RPC 000 33 00017 ENTER START Re peak cycle 1 shows on the display Press the Start Enter button to make the re peak cycle number blink and press the Dec Inc button to find the desired number of times...

Page 19: ...ger can store up to 10 different charge discharge profiles for your convenience and the stored profiles can be recalled quickly without having to go through the setup process BATT MEMORY 1 ENTER SET B...

Page 20: ...button for more than three seconds This screen indicate the saved profile Once you ve saved a charge profile you can load those settings to use later To load a memory you have to press the Start Ente...

Page 21: ...18V 0 00 0 00 0 00V MAIN 12 52V H4 190V L4 160V Start Enter INC Press the Start Enter button to enter the Lithium Battery Meter The screen indicate each cell s voltage The screen indicate the total v...

Page 22: ...ral safety timer automatically starts running at the same time This is programmed to prevent overcharge the battery if it proves to be faulty or if the termination circuit cannot detect the battery fu...

Page 23: ...oltage of input battery If the voltage drops below the value you set the operation forcibly terminated to protect the input battery Press and hold the Start Enter button for more than three seconds to...

Page 24: ...ection cable is linked to the Lithium battery being processed It comes to the final voltage when the program ended Present input voltage Displayed safety timer is turn on and duration of time in minut...

Page 25: ...low CELL error Low Voltage The internal temperature of the unit goes too high Int temp too hi DC in too low Input voltage less than 11V Input voltage higher than 30V DC in too high BATTERY WAS FULL Th...

Page 26: ...Po Ion Fe Li ion Fe Polymer cell count NiCd NiMH battery cell count Pb battery voltage Net weight Dimension DC 11 0 30 0 Volt Max Charge power 1000Watts Max Discharge power 40Watts 0 1 40 0A 0 1 8 0A...

Page 27: ...ximum circuit power chart Output 1 2 Per Output 5 0 3 0 2 0 1 5 1 2 1 0 5 0 3 0 2 0 1 5 1 2 1 0 5 0 3 5 2 3 1 7 1 4 1 2 5 0 5 0 4 2 3 3 2 8 2 4 2 1 1 9 1 7 1 5 1 4 1 3 1 2 1 1 20 0 20 0 20 0 20 0 19 0...

Page 28: ...quantity of charge 2 Ah if it is charged for 4 hours at 0 5 A or 15 minutes 1 4 h at 8 A C rating Capacity is also referred to as the C rating Some battery suppliers recommend charge and discharge cur...

Page 29: ...clusively for use with the types of battery stated in this Instruction Manual Hextronik accepts no liability of any kind if the charger is used for any purpose other than that stated We are unable to...