14 ·
LITHIUM BATTERY(LIPO/LILO/LIFE)PROGRAM
'STORAGE' control of lithium battery
This is for charging or discharging Lithium battery not to be used for the time being. The
program will determine to charge or discharge the battery to the certain voltage
depending on the voltage of the battery at its initial stage. They are different from the type
of the battery, 3.75V for LiIo, 3.85V for LiPo and 3.3V for LiFe per cell. If the voltage of
battery at its initial stage is over the voltage level to storage, the program will start to
discharge.
Number
of
cells
DEC
- +
Batt type
Stop
Elapsed
time
INC
Charge
or discharge
current
Supplied
capacity
DEC
Start
Enter
-
INC
+
Current
voltage
battery
'> 3 seconds '
Start
Enter
Number
of
cells
DEC
-
Batt type
Stop
elapsed
time
INC
+
Battery
voltage
DEC
Start
Enter
-
INC
+
Discharged
capacity
discharge
current
'> 3 seconds '
Start
Enter
Discharging Lithium battery
At this screen, you can set up the current and voltage of the battery
pack. Charging and discharging will make the batteries come to the
voltage level of storage state.
This screen shows the real-time status charging. Press Batt
Type/Stop key once to stop the charge process.
This displays the number of cells you set up and the processor
detects. R shows the number of cells detected by the charger and
S is the number of cells set by you at the previous screen. If both
numbers are identical you can start charging by press Start/Enter
button. If not, press Batt Type/Stop button to go back to previous
screen to carefully check the number of cells of the battery pack
before going ahead.
The value of discharge current on the left can not exceed 1C, and
the value on the right can not be under the voltage recommended
by the manufacturer to avoid deep discharging. Press Start/Enter
for more than 3 seconds to start discharging.
This shows the real-time status of discharging, you can press Batt
Type/Stop key to stop discharging.
This displays the number of cells you set up and the processor
detects. R shows the number of cells detected by the charger and
S is the number of cells set by you at the previous screen. If both
numbers are identical you can start charging by press Start/Enter
button. If not, press Batt Type/Stop button to go back to previous
screen to carefully check the number of cells of the battery pack
before going ahead.
Turnigy Mega 1000W