V01.00 | 2020/11
9
4.2
Process input data
Name
Byte.Bit-offset
Bit length Subindex access
supported
Data Type
Value
Description
Process data
0.4
28
False
Integer
-19999999…
134217727
134217721
Measurement
value is filtered.
134217722
Sensor muted.
134217723
Value underrun
134217724
Value overrun
134217725
Geometry error
134217726
No target
detected.
134217727
Internal Error
Process data 1
0.0
1
False
Boolean
false/true
Process data 2
0.1
1
False
Boolean
false/true