IO-Link Parameters
Standard parameters
10
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
4.3
Standard parameters
Name
Index
hex.
(dec.)
Sub-
index
hex.
(dec.)
Subindex
access
supported
Access Byte.
Bit-
Offset
Bit
length
Data Type Value Default Description
Min Cycle
Time
0x0
(0)
0x3
(3)
True
read
2.0
8
UInteger
IO-Link
Version ID
0x0
(0)
0x5
(5)
True
read
4.0
8
UInteger
17
Vendor ID 1
0x0
(0)
0x8
(8)
True
read
7.0
8
UInteger
Vendor ID 2
0x0
(0)
0x9
(9)
True
read
8.0
8
UInteger
Device ID 1
0x0
(0)
0xA
(10)
True
read
9.0
8
UInteger
Device ID 2
0x0
(0)
0xB
(11)
True
read
10.0
8
UInteger
Device ID 3
0x0
(0)
0xC
(12)
True
read
11.0
8
UInteger
Standard
Command
0x2
(2)
0x0
(0)
True
write 0.0
8
UInteger 0…
253
System command
128
Device Reset
129
Application Reset
130
Restore Factory Settings
The VDMA/Turck menu
selection is not reset.
160
Reset lowest recorded level
161
Reset highest recorded
level
253
Capture command for radar
monitor
Parameter
(write) Access
Lock
0xC
(12)
0x1
(1)
False
read/
write
0.0
1
Boolean
false/
true
Device access locks
Data Storage
Lock
0xC
(12)
0x2
(2)
False
read/
write
0.1
1
Boolean
false/
true
Device access locks
Local Para-
meterization
Lock
0xC
(12)
0x3
(3)
False
read/
write
0.2
1
Boolean
false/
true
Device access locks
Local User
Interface Lock
0xC
(12)
0x4
(4)
False
read/
write
0.3
1
Boolean
false/
true
Device access locks
Vendor Name 0x10
(16)
0x0
(0)
True
read
0.0
512
String
Turck
Vendor name
Vendor Text
0x11
(17)
0x0
(0)
True
read
0.0
512
String
www.
turck.
com
Additional manufacturer
information
Product Name 0x12
(18)
0x0
(0)
True
read
0.0
512
String
Manufacturer's device
designation