IO-Link Parameters
General parameters
8
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
4
IO-Link Parameters
4.1
General parameters
Parameter
Content
Vendor ID
317 (0x13D)
Device ID
524289 (0x80001)
IO-Link version
1.1
Bitrate
COM2 (38.4 kbit/s)
Minimum cycle time
5 ms
SIO supported
True
M-Sequence Capability
PREOPERATE = TYPE_1_V with 8 octets on-request data
ISDU supported
Block Parameter
True
Data Storage
True
ProfileCharacteristic