IO-Link Parameters
Parameters
18
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
Name
Index
hex.
(dec.)
Sub-
index
hex.
(dec.)
Subindex
access
supported
Access Byte.
Bit-
Offset
Bit
length
Data Type Value Default Description
Max. signal
amplitude
0x91
(145)
0x0
(0)
True
read/
write
0.0
16
UInteger 100…
9999
1000
Signals with higher
amplitude are ignored.
Min. signal
amplitude
0x92
(146)
0x0
(0)
True
read/
write
0.0
16
UInteger 100…
9999
100
Signals with lower
amplitude are ignored.
Frontground
suppression
0x94
(148)
0x0
(0)
True
read/
write
0.0
16
UInteger 1500
…
50000
1500
Signals in front of this
distance limit are ignored.
Background
suppression
0x95
(149)
0x0
(0)
True
read/
write
0.0
16
UInteger 1750
…
50250
50250 Signals behind this distance
limit are ignored.
IO-Link-Index 0xA8
(168)
0x1
(1)
True
read
0.0
16
UInteger 0…
149
0
Block transfer error details
0
No error
81
Configuration output 1
82
Configuration output 2
83
Polarity of switching
outputs
84
Units
86
Errorstate output 1
87
Errorstate output 2
89
Display color setpoints
90
Display color
91
Rotation of display
96
Setpoints output 1
97
Setpoints output 2
112
Damping (analog)
113
Damping (switching)
114
Temperature compensation
mode
115
Temperature compensation
value
118
Filter
120
On switching delay/
switching delay at FH1
121
Off switching delay/
switching delay at FL1
122
On switching delay/
switching delay at FH1
123
Off switching delay/
switching delay at FL2
136
Geometry
138
Display unit
139
Custom geometry:
Height nodes