V01.00 | 2021/07
29
Explanation
Options
Function
diSr
Display orientation
0°
Display rotated by 0°
180°
Display rotated by 180°
diSu
Measured value display
50
50 ms update time
200
200 ms update time
600
600 ms update time
Off
Display update deactivated
coLr
Display color
GrEn
Always green
rEd
Always red
G1ou
Green if ou1 is switched, otherwise red
r1ou
Red if ou1 is switched, otherwise green
G2ou
Green if ou2 is switched, otherwise red
r2ou
Red if ou2 is switched, otherwise green
G-cF
Green if the measured value is between switching
points cFL and cFH
r-cF
Red if the measured value is between switching
points cFL and cFH
Duni
Display of measured value and
unit
Measured value and unit are displayed alternately
(measured value: 4 s, unit: 1 s)
Off
Unit is not displayed.
ON
Unit is displayed.
cFH
Virtual upper switching point
Upper switching point at which the display changes
color (if display color G-cF or r-cF is selected)
(default in distance mode: 0.5 × measuring range)
cFL
Virtual lower switching point
Lower switching point at which the display changes
color (if display color G-cF or r-cF is selected)
(default in distance mode: 0.75 × measuring range)
PASS
Password protection
Define password and activate password protection
0000
No password
rES
Reset
FacT
Reset the parameters to the factory settings
Undo
Reset the parameters to previous settings (last device
start)
SOF
Soft menu version
StD
Standard menu guidance
VDMA
VDMA menu guidance
OPHr
Operating hours counter
Display of operating hours in years (y), days (d) and
hours (h)