V01.00 | 2021/07
43
14.3
Technical data – LRS510-10-…-LI2UPN8-H1141
Technical data
LRS510-10-34…
LRS510-10-51…
LRS510-10-57…
LRS510-10-69…
Ident No.
100012730
100012729
100012723
100012722
Radar data
Frequency range
122…123 GHz
Range
35…1000 cm
Resolution
1 mm
Minimum size
measuring range
500 mm
Minimum size
switching range
500 mm
Linearity tolerance
≤ ± 0.1 %
Edge length of the
standard target
100 mm
EIRP radiant power
10 dBm
Opening angle
10°
6°
Repetition accuracy
2 mm
Hysteresis
≤ 50 mm
Electrical data
Operating voltage
18…33 VDC
Ripple
< 10 % U
SS
DC rated operational
current
≤ 250 mA
No-load current
≤ 100 mA
Residual current
≤ 0.1 mA
Short-circuit
protection
Yes/cyclic
Reverse polarity
protection
Yes
Communication
protocol
IO-Link
Output function
NC/NO programmable, PNP/NPN, analog output
Output 2
Analog output
Current output
Default: 4…20 mA
Voltage output
Default: 0…10 V
Load resistance
current output
≤ 0.5 kΩ
Load resistance
voltage output
≥ 8 kΩ
Voltage drop at I
e
≤ 2 V
Switching frequency
≤ 10 Hz
Typical response time
< 10 ms
IO-Link
IO-Link specification
V1.1
IO-Link port type
Class A