16
Setting SP1 (Set point):
The SP value determines the
DUTY CYCLE
the solenoid will operate at when the gate pressure is reached.
The SP value is not the amount of boost pressure your turbo will produce. This is a value between 0
– 99. The larger the value, the
more boost the turbocharger will produce. Start the setup by increasing the SP value to 20. Bring the car onto boost and see what the
maximum boost pressure is. Increase the value in small increments until you achieve your desired boost pressure. The SP value can
also be adjusted while the car is on boost however, instead of the SP value being displayed, the boost pressure will be displayed so you
know what pressure you are achieving. This is the easiest way to set your set points.
Press the
KNOB
to enter the menu and adjust the
values rotating the knob
LEFT
or
RIGHT
. Press the
KNOB
again to save the desired setting.
Setting GP1 (Gate pressure):
This feature helps bring boost on faster at lower rpm and will give an increase in torque. Start by setting
the gate pressure 5 PSI below the desired boost pressure with the corresponding SP value e.g. if the desired boost pressure is 15 PSI,
set the gate pressure to 10 PSI first and adjust from there. Adjust the value higher to increase the response of the turbocharger or
decrease the value to reduce the response. If this setting is too close to target boost, you will get a boost spike. Press the
KNOB
to
enter the menu and adjust the values by rotating the knob
LEFT
or
RIGHT
. Press the
KNOB
again to save the desired setting.
Setting SN1 (Sensitivity):
The sensitivity is how sensitive the E-Boost Street is to changes in the boost curve. Under normal
circumstances the sensitivity is left at the factory set level of 20. If your boost curve is wavy through the rev range, reduce the sensitivity,
if your boost curve drops off at the end of the rev range, increase the sensitivity.
Note:
do not increase this value higher than 30. Press
the
KNOB
to enter the menu and adjust the values by rotating the knob
LEFT
or
RIGHT
. Press the
KNOB
again to save the desired
setting.