Location

 

•  This oven must be installed in an area of adequate air supply.  To ensure correct ventilation for the 

motor and controls the following minimum installation clearances are to be adhered to: 

•  This oven must be fitted on supplied legs in all installations, unless installed on a manufacturers 

stand. 

•  Position the oven in its working position. 
•  Use a spirit level to ensure oven is level from side to side and front to back.  (If this is not carried 

out, uneven cooking could occur).  The legs used with bench/floor mounting or provided with 
stands are adjustable and will require adjusting in levelling the unit.   

•  The unit should be positioned such that the operating panel and oven shelves are easily reachable 

for loading and unloading.   

•  Adequate ventilation is essential.  DO NOT obstruct the air flow around the ventilation slots. 

 

Electrical Connection 

This oven is fitted with an approved power supply cord via an electrical junction box at the right hand 
rear of the unit.  Should changing of the cord be necessary then follow the instructions given below: 
•  Remove right hand side panel to allow access to the terminal block and strain relief cable clamp.   
•  The cable can be fitted through the small grommet and held by the cable clamp.   

Installation

 

Important:

 

THE VENT LOCATED ON THE OVEN TOP MUST NEVER BE OBSTRUCTED.   

Supply Requirements (continued)

 

 

Natural Gas 

LPG 

Natural Gas - UK 

Propane - UK 

 

 

 

(G20) 

(G31) 

Operating Pressure 

0.85 kPa 

2.25 kPa 

10 mbar 

35 mbar 

 

(3.5” w.c.) 

(9.0” w.c.) 

 

 

Gas Connection 

½” BSP Female 

½” BSP Female 

 

½” NPT Female (Canada only) 

 

Electrical Connection 

220-240 Volts AC, 50Hz, 0.7A, 0.168kW, Single Phase 

220 Volts AC, 60Hz, 0.7A, 0.168kW, Single Phase 

110 Volts AC, 60Hz, 2.0A, 0.12kW, Single Phase 

Cold Water Connection 

¾” B.S.P. (80psi maximum pressure) 

Supply Pressure 

1.13 kPa 

2.75 kPa 

20 mbar 

37 mbar 

 

(4½” w.c.) 

(11” w.c.) 

 

 

Top 

200mm / 8” (or 600mm / 24” from a combustible surface) 

Rear 75mm 

3” 

Left-hand side 

75mm / 3” 

Right-hand side 

75mm / 3”   (Fixed installations require at least 500mm (20”) clearance at 

the right hand side for service accessibility.) 

Summary of Contents for G32M

Page 1: ...F24824 15 G32M CONVECTION OVEN G32MS CONVECTION OVEN INSTALLATION OPERATION MANUAL...

Page 2: ...9 1007 Ph 09 574 3150 Fax 03 389 1276 Fax 09 574 3159 AUSTRALIA Victoria New South Wales Moffat Pty Limited Moffat Pty Limited 740 Springvale Road 3 142 James Ruse Drive Rose Hill Mulgrave Melbourne P...

Page 3: ...Connection Gas Connection Water Connection Before Use Lighting Instructions Reversing the Door Specifications 7 Operation 8 Description of Controls Baking Roast n Hold Oven Racks Cooking Guide 12 Bak...

Page 4: ...n is designed to meet the technical safety and health standards of the United Kingdom U S A Europe Canada Australia and New Zealand Instructions to be followed in the event the user smells gas are to...

Page 5: ...air requirements Natural Gas G20 UK 10m hr Propane Gas G31 UK 9m hr Components having adjustments protected e g paint sealed by manufacturer are only allowed to be adjusted by an authorised service a...

Page 6: ...ia an electrical junction box at the right hand rear of the unit Should changing of the cord be necessary then follow the instructions given below Remove right hand side panel to allow access to the t...

Page 7: ...If the manual addition of water into the oven for humidification or steaming effect on baked product is required the unit s water connection can be used A cold water supply should be fitted to the wa...

Page 8: ...cure the door hinges and oven door to the right hand side of the oven door opening If alignment of the door is necessary the five screws along the bottom of the oven can be loosened and the door moved...

Page 9: ...67 kg hr Injector Size 2 80 mm 1 80 mm 2 60 mm 1 55 mm Supply Pressure 1 13 kPa 2 75 kPa 20 mbar 37 mbar 4 w c 11 w c Operating Pressure 0 85 kPa 2 25 kPa 10 mbar 35 mbar 3 5 w c 9 0 w c Gas Connectio...

Page 10: ...tivate Roast n Hold function Switch illuminates when ON Roast Timer 3 Hour roast timer Indicator illuminates when time up 0 reached Product is held at 75 C 165 F Steam Switch Push switch to activate w...

Page 11: ...ll illuminate when the door is opened 4 Set bake timer to desired time To set timer turn knob clockwise to the required time At any stage the time can be adjusted in either direction For settings less...

Page 12: ...mer can be set when convenient but will not start working until the oven control is set and the Roast n Hold switch is depressed switch illuminated 5 Depress roast switch Depress the Roast n Hold swit...

Page 13: ...p to each oven rack and stops it s inadvertent removal during normal operation To fit the oven racks follow the steps shown in the diagram below To remove oven racks reverse the procedure 1 2 3 4 5 1...

Page 14: ...12 mins Small Cakes 165 8 12 mins Butter Cakes 160 35 mins Fruit Loaf 150 40 50 mins Macaroons 160 15 20 mins Biscuits 140 12 20 mins Shortbread 130 15 20 mins Scones 200 10 12 mins Madeira 165 35 50...

Page 15: ...Chicken under 1kg over 1kg 50 65 min 40 50 min Roast n Hold This system will automatically cook food for a set time then hold the oven at a preset temperature indefinitely to maintain food at a servi...

Page 16: ...en Ensure that the silk gasket is fitted before replacing the lamp glass Oven Seals To remove hold at their centre point and pull forward until they unclip Remove side seals first then top and bottom...

Page 17: ...er not set correctly For settings less than 10 minutes first set to greater setting then turn back to desired setting Roast timer does not time down Roast n Hold button not depressed Depress Roast n H...

Page 18: ...rmostat 024802 Microswitch 003002 Oven Lamp Glass 003434 Silk Gasket 013520 Oven Lamp Assembly 40W Miniature Edison Screw 220 240V 023216 Oven Lamp Assembly 40W Edison Screw 110V 013521 Oven Light Bul...

Page 19: ...Outer Glass G32M 002340 Door Inner Glass G32M 024713 Door Handle G32MS 023063 Door Glass G32MS Racks 015575 Oven Side Rack LH 015656 Fan Baffle 015168 Oven Rack Gas Type Conversion Kits 025901 Natural...

Page 20: ...OR C T STAT 4 5 M 2 1 3Hr TIMER HEATING 6 3 1 3 5 7 HOLD 4 HOLD 4 2 8 6 2 HOLD 3 1 2 THERMOSTAT HOLD 1 2 1 4 3 2 1 IGNITION BOX 2 1 2 1 NO 1Hr TIMER GAS SOLENOIDS 1 2 NPT MALE 10mm ID HOSE GAS 3 8 inc...

Page 21: ...AL YELLOW BROWN GREEN BLUE NEUTRAL EARTH GROUND B 2 OVER TEMP 1 POWER SPARK INJECTOR WATER SOLENOID SENSOR T11 IGNITION BOX T2 T1 T3 T4 T6 T5 T10 T9 T15 T16 T12 T13 T14 HEATING LIGHTS TIME UP WATER 1...

Page 22: ...GAS 3 8 inch WATER GAS REGULATOR CONNECTIONS YELLOW ELECTRICAL BROWN GREEN BLUE NEUTRAL EARTH GROUND B POWER WATER SPARK INJECTOR WATER SOLENOID GAS SOLENOIDS SENSOR T11 IGNITION BOX T4 T3 T2 T1 T6 T5...

Page 23: ......

Page 24: ......

Reviews: