turbofan G32M Operation Manual Download Page 2

MANUFACTURED BY  

Moffat Limited 
PO Box 10001 
Christchurch 
New Zealand 
Ph: 

(03) 389 1007 

Fax: 

(03) 389 1276 

 
 

WORLD-WIDE BRANCHES

 

 

UNITED KINGDOM 

Blue Seal 
Units 6-7, Mount Street Business Park 
Mount Street, Nechells 
Birmingham B7 5QU 
Ph: 

(121) 327 5575 

Fax: 

(121) 327 9711 

 
 

UNITED STATES 

 
Moffat Inc 
3765 Champion Blvd 
Winston-Salem 
North Carolina 27115 
Ph: 

(336) 661 0257 

Fax: 

(336) 661 9546 

 
 

CANADA 

 

Serve Canada 
22 Ashwarren Road 
Downview 
Ontario M3J1Z5 

Toll Free:800 263 1455 
Ph: 

(416) 631 0601 

Fax: 

(416) 631 0315 

[email protected]  
www.servecanada.com 
www.moffat.com 

 
 

NEW ZEALAND

 

 

Christchurch

 

Auckland

 

Moffat Limited 

Moffat Limited 

PO Box 10-001 

4 Waipuna Road 

16 Osborne Street 

Mt Wellington 

Christchurch Auckland 
Ph: 

(03) 389 1007 

Ph: 

(09) 574 3150 

Fax: 

(03) 389 1276 

Fax: 

(09) 574 3159 

 
 

AUSTRALIA

 

 

Victoria

  

New South Wales

 

Moffat Pty Limited 

Moffat Pty Limited 

740 Springvale Road 

3/142 James Ruse Drive, Rose Hill 

Mulgrave, Melbourne 

PO Box 913, Smithfield 

Victoria 3171 

Sydney, N.S.W. 2142 

Ph: 

(03) 9518 3888 

Ph:   

(02) 8833 4111 

Fax: 

(03) 9518 3838 

Fax:  

(02) 8833 4133 

 

Western Australia

 

Queensland

 

Moffat Pty Limited 

Moffat Pty Limited 

67 Howe Street 

30 Prosperity Place 

Osbourne Park 

Geebung, Brisbane 

WA 6017 

 

Queensland 4034 

Ph: 

(08) 9202 6820 

Ph:  

(07) 3630 8600 

Fax: 

(08) 9202 6836 

Fax    

(07) 3630 8623 

The reproduction or copying of any part of this manual by any means whatsoever is strictly forbidden unless authorized previously in 
writing by the manufacturer. 
 
In line with policy to continually develop and improve its products, Moffat Ltd. reserves the right to change the specifications and 
design without prior notice. 

©  Copyright Moffat Ltd.  November 2006. 

Summary of Contents for G32M

Page 1: ...F24824 15 G32M CONVECTION OVEN G32MS CONVECTION OVEN INSTALLATION OPERATION MANUAL...

Page 2: ...9 1007 Ph 09 574 3150 Fax 03 389 1276 Fax 09 574 3159 AUSTRALIA Victoria New South Wales Moffat Pty Limited Moffat Pty Limited 740 Springvale Road 3 142 James Ruse Drive Rose Hill Mulgrave Melbourne P...

Page 3: ...Connection Gas Connection Water Connection Before Use Lighting Instructions Reversing the Door Specifications 7 Operation 8 Description of Controls Baking Roast n Hold Oven Racks Cooking Guide 12 Bak...

Page 4: ...n is designed to meet the technical safety and health standards of the United Kingdom U S A Europe Canada Australia and New Zealand Instructions to be followed in the event the user smells gas are to...

Page 5: ...air requirements Natural Gas G20 UK 10m hr Propane Gas G31 UK 9m hr Components having adjustments protected e g paint sealed by manufacturer are only allowed to be adjusted by an authorised service a...

Page 6: ...ia an electrical junction box at the right hand rear of the unit Should changing of the cord be necessary then follow the instructions given below Remove right hand side panel to allow access to the t...

Page 7: ...If the manual addition of water into the oven for humidification or steaming effect on baked product is required the unit s water connection can be used A cold water supply should be fitted to the wa...

Page 8: ...cure the door hinges and oven door to the right hand side of the oven door opening If alignment of the door is necessary the five screws along the bottom of the oven can be loosened and the door moved...

Page 9: ...67 kg hr Injector Size 2 80 mm 1 80 mm 2 60 mm 1 55 mm Supply Pressure 1 13 kPa 2 75 kPa 20 mbar 37 mbar 4 w c 11 w c Operating Pressure 0 85 kPa 2 25 kPa 10 mbar 35 mbar 3 5 w c 9 0 w c Gas Connectio...

Page 10: ...tivate Roast n Hold function Switch illuminates when ON Roast Timer 3 Hour roast timer Indicator illuminates when time up 0 reached Product is held at 75 C 165 F Steam Switch Push switch to activate w...

Page 11: ...ll illuminate when the door is opened 4 Set bake timer to desired time To set timer turn knob clockwise to the required time At any stage the time can be adjusted in either direction For settings less...

Page 12: ...mer can be set when convenient but will not start working until the oven control is set and the Roast n Hold switch is depressed switch illuminated 5 Depress roast switch Depress the Roast n Hold swit...

Page 13: ...p to each oven rack and stops it s inadvertent removal during normal operation To fit the oven racks follow the steps shown in the diagram below To remove oven racks reverse the procedure 1 2 3 4 5 1...

Page 14: ...12 mins Small Cakes 165 8 12 mins Butter Cakes 160 35 mins Fruit Loaf 150 40 50 mins Macaroons 160 15 20 mins Biscuits 140 12 20 mins Shortbread 130 15 20 mins Scones 200 10 12 mins Madeira 165 35 50...

Page 15: ...Chicken under 1kg over 1kg 50 65 min 40 50 min Roast n Hold This system will automatically cook food for a set time then hold the oven at a preset temperature indefinitely to maintain food at a servi...

Page 16: ...en Ensure that the silk gasket is fitted before replacing the lamp glass Oven Seals To remove hold at their centre point and pull forward until they unclip Remove side seals first then top and bottom...

Page 17: ...er not set correctly For settings less than 10 minutes first set to greater setting then turn back to desired setting Roast timer does not time down Roast n Hold button not depressed Depress Roast n H...

Page 18: ...rmostat 024802 Microswitch 003002 Oven Lamp Glass 003434 Silk Gasket 013520 Oven Lamp Assembly 40W Miniature Edison Screw 220 240V 023216 Oven Lamp Assembly 40W Edison Screw 110V 013521 Oven Light Bul...

Page 19: ...Outer Glass G32M 002340 Door Inner Glass G32M 024713 Door Handle G32MS 023063 Door Glass G32MS Racks 015575 Oven Side Rack LH 015656 Fan Baffle 015168 Oven Rack Gas Type Conversion Kits 025901 Natural...

Page 20: ...OR C T STAT 4 5 M 2 1 3Hr TIMER HEATING 6 3 1 3 5 7 HOLD 4 HOLD 4 2 8 6 2 HOLD 3 1 2 THERMOSTAT HOLD 1 2 1 4 3 2 1 IGNITION BOX 2 1 2 1 NO 1Hr TIMER GAS SOLENOIDS 1 2 NPT MALE 10mm ID HOSE GAS 3 8 inc...

Page 21: ...AL YELLOW BROWN GREEN BLUE NEUTRAL EARTH GROUND B 2 OVER TEMP 1 POWER SPARK INJECTOR WATER SOLENOID SENSOR T11 IGNITION BOX T2 T1 T3 T4 T6 T5 T10 T9 T15 T16 T12 T13 T14 HEATING LIGHTS TIME UP WATER 1...

Page 22: ...GAS 3 8 inch WATER GAS REGULATOR CONNECTIONS YELLOW ELECTRICAL BROWN GREEN BLUE NEUTRAL EARTH GROUND B POWER WATER SPARK INJECTOR WATER SOLENOID GAS SOLENOIDS SENSOR T11 IGNITION BOX T4 T3 T2 T1 T6 T5...

Page 23: ......

Page 24: ......

Reviews: