10 

Contacts And Relay Terminal Block J2 

Enable contact input consensus 14.15 terminals.

 

Is used to activate the control unit remotely, it can be turned on and off remotely. 

The unit is supplied with a jumper on the two terminals 14:15, without it will not turn 
on. 

Fan contact 12.13 input terminals. 

Indicated by the control unit that the plant has been started and is in operation. 

The unit is supplied with a jumper on two 12:13 terminals to simulate the state of the 
plant, as if the fan was turned on. 

Alarm Relay K1 4.5 terminals. 

The relay is normally closed, opens in case of alarms, and opens with the control unit off 
or in the absence of power. 

The alarms that open the relays are: 

Problem with solenoid valves E06-E08.  

Maintenance interval has been reached.  

If one of these occurs, the relay is activated. 

Terminal Table 

Terminal n.

 

Description

 

Terminal n.

 

Description

 

Power supply 115 – 230 Vac 

32 

Solenoid 2 output 

Power supply 115 – 230 Vac 

33 

Solenoid 3 output 

Earth (GND) 

34 

Solenoid 4 output 

Relay contact 1 

35 

Solenoid 5 output 

Relay contact 1 

36 

Solenoid 6 output 

Relay contact 2 

37 

Solenoid 7 output 

Relay contact 2 

38 

Solenoid 8 output 

12 

Fan input 

39 

Solenoid 9 output 

13 

Fan input 

40 

Solenoid 10 output 

14 

Enable input 

41 

Solenoid 11 output 

15 

Enable input 

42 

Solenoid 12 output 

 

 

43 

Solenoid 13 output 

Solenoid Valve Gnd 

44 

Solenoid 14 output 

30 

Solenoid Valve Common 

45 

Solenoid 15 output 

31 

Solenoid 1 output 

46 

Solenoid 16 output 

 
If the sequencer is in G2 version with reinforced transformer, connect two solenoid valves in parallel 
to each terminal. 

Fuse Table 

Voltage 

Value 

230 Vac 

1 A 

115 Vac 

1 A 

24 Vdc / Vac 

3 A 

 

Summary of Contents for E1T 16

Page 1: ...T USER MANUAL 01 03 2016 Manual Release 1 24 Hardware Release 1 3 TURBO s r l Electronic Control Systems for Dust Collectors e mail info turbocontrols it web www turbocontrols eu TEL 39 0 362 574024 F...

Page 2: ...e IK07 2 Joule EN62262 Performance Of The Device LED display with 7 segments 3 digits 0 8 each Operating times expressed in seconds with selectable ranges for any application Power supplier 115 230 Va...

Page 3: ...ally closed The activation of a solenoid valves causes them to open and consequently let out a jet of air Alarm Relays The alarm relays has two voltage free contacts on terminals 4 5 Relay 1 and 6 7 r...

Page 4: ...oned in a place easily accessible Before working on the equipment to perform any operation switch off the magneto thermic differential switch For electric operations always remove voltage wait 30 seco...

Page 5: ...correct use of the device may cause damage to the device or to the devices connected to it Furthermore incorrect use or tampering with the device may cause injury Waterproofness of the casing is guara...

Page 6: ...o select and then and increase or decrease the values The OK button is used to confirm data and reset alarms If the button is pressed during ordinary operation the activity hour meter is displayed The...

Page 7: ...ping the fan Possible values 01 99 step 1 Default 01 F14 Post cleaning mode pause time fan off Possible values 001 999 step 1 Default 010 F15 Maintenance frequency expressed in tens of hours e g 1 10h...

Page 8: ...detected To use 115V valves switch the device off and move the output voltage selection jumper to 115V If the jumper is in the correct position press OK then SET select the F05 function with and set 1...

Page 9: ...ing pages will then appear OFF if the enabling contact is open 14 15 0 if the enabling contact 14 15 is closed and the fan is off Operative Mode The device works as a programmable cycle sequencer The...

Page 10: ...9 Connection Diagram...

Page 11: ...Maintenance interval has been reached If one of these occurs the relay is activated Terminal Table Terminal n Description Terminal n Description 1 Power supply 115 230 Vac 32 Solenoid 2 output 2 Powe...

Page 12: ...11 Jumper Configuration Power Input 115 230 VAC 115 VAC 230 VAC Jumper Configuration Output 115 VAC 230 VAC 24 VAC 24 VDC...

Page 13: ...12 Installation Casing Dimensions 4 8 Outputs Weight 1 8 Kg...

Page 14: ...13 Installation Casing Dimensions 12 16 Outputs Weight 2 1 Kg...

Page 15: ...of cycles after fan stop 1 F14 Pause time between solenoid valves in cycle with fan off 010 F15 Maintenance frequency in 10h 1 10h 100 1000h 100 F16 Maintenance deadline alarm on 1 or off 0 0 F17 Main...

Page 16: ...d vale output voltage agree Check wiring between sequencer and solenoid valves Do alarm messages appear Check the alarm code with the table Do the alarms fail to activate signalling devices System wir...

Page 17: ...Product Options All Complies with the following directives Electromagnetic Compatibility Directive 2014 30 EU meeting EU harmonised standards EN61000 6 2 2005 class B of Standard EN61000 6 4 2001 Low...

Reviews: