5
Display / Keypad
There are four round buttons on the front panel for controlling the device on the front
panel. The display will appear similar to the following when it is turned on.
The SET button enables to enter and exit the
programming menu, and activate the manual test of
solenoid valve selected in function F06.
The + and – buttons enable to scroll functions from
F01 to Fxx. After entering one of the Fxx functions use
the OK button to select and then + and - increase or
decrease the values.
The OK button is used to confirm data and reset alarms.
If the + button is pressed during ordinary operation,
the activity hour meter is displayed.
The – Button pressed during the ordinary operation,
displays the counts partial hours of activity.
Menu Diagram
Press SET, the letter F flashes.
Press + and – to select the required function.
Press OK to confirm.
Increase or decrease the value of the parameter with +
and - buttons.
Holding down the + and – buttons to scroll through all
the functions until the end of the left or right.
Press OK to confirm and exit.
Press SET again to exit programming mode.