C h a r g e D i s p l a c e m e n t P r o b e E 9 T r b F o r D u s t C o n t r o l
I n M n 2 5 S T S C
e n R e v . 0 0
T U R B O s . r . l .
D u s t F i l t e r C o m p o n e n t s
V i a P o 3 3 / 3 5 2 0 8 1 1 C e s a n o M a d e r n o ( M B ) I t a l y T e l + + 3 9 0 3 6 2 5 7 4 0 2 4 F a x + + 3 9 0 3 6 2 5 7 4 0 9 2
9
Output Status And Functionality
Status
Alarm 1
Output U1 On = exceeded during the normal measure of the factory value
(see table) or the self acquired multiplied 5 times (multiplication factor x 5).
Alarm 2
Output U2 On = exceeded during the normal measure of the factory value
(see table) or the self acquired multiplied 10 times (multiplication factor x 10).
Fault
output U3 On = failed the test operation, triggered by a negative pulse (min 0.5
sec.) on pin 3 (Test Input): If pin 3 is connected to a short time to pin 2 (Negative
Power Supply) is automatically activated the test procedure that verifies the proper
operation of the entire probe.
The lack of activation of the output U3 and its Led L4 indicate proper operation of
the probe and passing the test
Outputs
U1 (pin 7) Normally open output with J2 opened; normally closed with J2 closed.
U2 (pin 8) Normally open output with J2 opened; normally closed with J2 closed.
U3 (pin 9) Normally open output with J2 opened; normally closed with J2 closed.