U s e A n d M a i n t e n a n c e I n s t r u c t i o n s
C h a r g e D i s p l a c e m e n t P r o b e E 9 T r b F o r D u s t C o n t r o l
8
T U R B O s . r . l .
D u s t F i l t e r C o m p o n e n t s
V i a P o 3 3 / 3 5 2 0 8 1 1 C e s a n o M a d e r n o ( M B ) I t a l y T e l + + 3 9 0 3 6 2 5 7 4 0 2 4 F a x + + 3 9 0 3 6 2 5 7 4 0 9 2
I n M n 2 5 S T S C
R e v . 0 0 e n
Accessories
Ex t en sio n s A n d A d a p t a tio ns F o r El e c tro d e I ns ta ll a tio n O n Pi p el in e s O f V ari o u s Di a m e te rs
L e n g h t
5 0 m m
1 0 0 m m
2 0 0 m m
4 0 0 m m
T h r e a d
M 4 m 1 0 m m
M a t e r i a l
I n o x S t e e l
d . 8 m m
The extensions of the electrodes must be joined together using a medium
strength thread locker to prevent loosening due to vibration, shock and
temperature fluctuations.
Startup
After powering up the probe and verified the green led L1, it is necessary to wait
for a warm-up time of 3 minutes, during which the probe is measuring but the
outputs are disabled.
After this period of time, if the jumper J1 is left OFF, disengaged, the probe will
operate in manual mode with preset thresholds from the default settings.
If the jumper J1 is inserted, the probe will work with thresholds set
automatically. in this condition, the probe will wait for the press of the button
P1, this state will be indicated by the led L2 mode "a" that is slowly blinking.
To start the self-acquisition: hold down P1 button for 5 seconds, the led will light
steadily L2 (mode "b"), and wait until the led turned off after about 4 minutes,
at this point the acquisition will be completed and the values will be stored in a
solid-state memory, which will keep them even if the probe will be de-energized.
N . B . v a l u e s a r e , o b t a i n e d f o r t h e p r o b e , t h e r e f e r e n c e f o r t h e a c t i v a t i o n o f t h e o u t p u t s , t h e n b e
u n d e r s t o o d a s o p e r a t i n g v a l u e s w i t h " r e g u l a r " q u a n t i t y o f d u s t , s o i t i s r e c o m m e n d e d t o p e r f o r m
t h e s e l f - a c q u i s i t i o n b y c h o o s i n g t h e m o m e n t c o n s i d e r e d m o s t s u i t a b l e d u r i n g p r o c e s s i n g .
If you want to store new values (eg. changes of working conditions), run new self-
acquisition by pressing P1 as described above.