U s e   A n d   M a i n t e n a n c e   I n s t r u c t i o n s

C h a r g e   D i s p l a c e m e n t   P r o b e   E 9 T r b   F o r   D u s t   C o n t r o l

 

8  

T U R B O   s . r . l .

    D u s t   F i l t e r   C o m p o n e n t s  

V i a   P o   3 3 / 3 5   2 0 8 1 1   C e s a n o   M a d e r n o   ( M B )   I t a l y     T e l   + + 3 9   0 3 6 2   5 7 4 0 2 4     F a x   + + 3 9   0 3 6 2   5 7 4 0 9 2  

I n M n   2 5   S T S C

R e v . 0 0     e n  

 

Accessories 

Ex t en sio n s  A n d  A d a p t a tio ns   F o r  El e c tro d e   I ns ta ll a tio n  O n  Pi p el in e s  O f  V ari o u s  Di a m e te rs  

 

L e n g h t  

5 0   m m  

1 0 0   m m  
2 0 0   m m  
4 0 0   m m  

 

T h r e a d  

M 4   m   1 0   m m  

 

 

M a t e r i a l  

I n o x   S t e e l  

d .   8   m m  

 

 

 

 

 

The extensions of the electrodes must be joined together using a medium 

strength thread locker to prevent loosening due to vibration, shock and 
temperature fluctuations. 

Startup 

After powering up the probe and verified the green led L1, it is necessary to wait 

for a warm-up time of 3 minutes, during which the probe is measuring but the 
outputs are disabled. 

After this period of time, if the jumper J1 is left OFF, disengaged, the probe will 

operate in manual mode with preset thresholds from the default settings. 

If the jumper J1 is inserted, the probe will work with thresholds set 

automatically. in this condition, the probe will wait for the press of the button 
P1, this state will be indicated by the led L2 mode "a" that is slowly blinking. 

To start the self-acquisition: hold down P1 button for 5 seconds, the led will light 

steadily L2 (mode "b"), and wait until the led turned off after about 4 minutes, 
at this point the acquisition will be completed and the values will be stored in a 
solid-state memory, which will keep them even if the probe will be de-energized. 

N . B .   v a l u e s   a r e ,   o b t a i n e d   f o r   t h e   p r o b e ,   t h e   r e f e r e n c e   f o r   t h e   a c t i v a t i o n   o f   t h e   o u t p u t s ,   t h e n   b e        

u n d e r s t o o d   a s   o p e r a t i n g   v a l u e s   w i t h   " r e g u l a r "   q u a n t i t y   o f   d u s t ,   s o   i t   i s   r e c o m m e n d e d   t o   p e r f o r m    

t h e   s e l f - a c q u i s i t i o n   b y   c h o o s i n g   t h e   m o m e n t   c o n s i d e r e d   m o s t   s u i t a b l e   d u r i n g   p r o c e s s i n g   .

 

If  you  want  to  store  new  values  (eg.  changes  of  working  conditions),  run  new  self-
acquisition by pressing P1 as described above.

 

 

 

 

 

 

 

 

 

Summary of Contents for 3201058

Page 1: ...For Dust Control I n Mn 25 STSC en Rev 00 TURBO s r l Du st Fi l t er C om p on en t s Vi a P o 3 3 3 5 2 0 8 1 1 Ce san o M a de rn o M B I t al y Te l 3 9 0 3 6 2 5 7 4 0 2 4 Fa x 3 9 0 3 6 2 5 7 4...

Page 2: ...4 Accessories ____________________________________________________________________ 8 Startup_________________________________________________________________________ 8 Output Status And Functionality...

Page 3: ...the electrode induced by the electrical charges carried by dust immersed in a gaseous fluid The amount of electric charge dynamically induced on the electrode is proportional to the amount of dust pre...

Page 4: ...the probe and other equipment Installation Fixing On Vertical Duct Fixing On Horizontal Duct 1 Threaded Sleeve Gas 2 Continue Welding On The Circumference Of The Sleeve The triboelectric probe must be...

Page 5: ...e probe must exceed of the diameter of the pipe In order to minimize any dust deposits on the electrode is not recommended mounting the probe with the enclosure underneath the pipeline The electrode m...

Page 6: ...1 1 Ce san o M a de rn o M B I t al y Te l 3 9 0 3 6 2 5 7 4 0 2 4 Fa x 3 9 0 3 6 2 5 7 4 0 9 2 I n Mn 25 STSC Rev 0 0 en Installation Of The Probe On Discharge Duct For Different Exhaust Fumes Temper...

Page 7: ...sion 1 Collar For The Fastening Of The Electrode 2 Support For Probe Electrode Made Of Teflon To Fix On The Conduct 3 Support For Probe With Sleeve To Be Fixed On The Conduct 4 Continuous Welding On S...

Page 8: ...jumper J1 is left OFF disengaged the probe will operate in manual mode with preset thresholds from the default settings If the jumper J1 is inserted the probe will work with thresholds set automatica...

Page 9: ...l measure of the factory value see table or the self acquired multiplied 10 times multiplication factor x 10 Fault output U3 On failed the test operation triggered by a negative pulse min 0 5 sec on p...

Page 10: ...flashing serial connection activated Jumpers Description J1 Operation range only for PWM 4 20 mA output J1 open full scale 20 mA at 10 mg m3 or 2 mg m3 for probe E9PRL006 J1 closed full scale 20 mA at...

Page 11: ...available versions Test Procedure To test the proper operation of the probe connect pin 3 test input to pin 2 negative power for a longer time than 0 5 sec The led relating to fault threshold led 4 an...

Page 12: ...2 0 8 1 1 Ce san o M a de rn o M B I t al y Te l 3 9 0 3 6 2 5 7 4 0 2 4 Fa x 3 9 0 3 6 2 5 7 4 0 9 2 I n Mn 25 STSC Rev 0 0 en Electrical Connections Ground Connection Use the cable that is supplied...

Page 13: ...Signals The probe must be supplied with a voltage between 20 and 30V DC The opto isolated open collector outputs protected by a self resetting fuse accept a maximum voltage 48 VAC and a maximum curre...

Page 14: ...the powder as a function of time In abscissa there is the time variable seconds while in the ordinate is placed the induced current from the charges carried by the gaseous fluid or alternatively and...

Page 15: ...ns Alarm 3 threshold fault Automatically activated by the function of test Alarm outputs n 3 outputs with solid state relay fuse protected auto resetting Maximum current outputs 100 mA Maximum applica...

Page 16: ...status of the stylus electrode of the probe if there are accumulations of dirt and or condensation between the electrode and the metal mount nipple to the container which could offset measurements Per...

Page 17: ...R B O S R L The manufacturer s address V i a P o 3 3 3 5 2 0 8 1 1 C e s a n o M a d e r n o I t a l y Declares that the product T r i b o e l e c t r i c P r o b e E 9 T Complies with the following...

Reviews: