U s e A n d M a i n t e n a n c e I n s t r u c t i o n s
C h a r g e D i s p l a c e m e n t P r o b e E 9 T r b F o r D u s t C o n t r o l
I n M n 2 5 S T S C
e n R e v . 0 0
T U R B O s . r . l .
D u s t F i l t e r C o m p o n e n t s
V i a P o 3 3 / 3 5 2 0 8 1 1 C e s a n o M a d e r n o ( M B ) I t a l y T e l + + 3 9 0 3 6 2 5 7 4 0 2 4 F a x + + 3 9 0 3 6 2 5 7 4 0 9 2
1 5
Technical Features
Power supply
20 / 30 Vdc
Maximum power consumption
1 W
Resolution
0,1 mg/m
3
, 0,01 mg/m
3
see versions
Range settings
Automatic / Manual
Size dust particles
> of 0.3 µm
Type of measurable products
Dust particles in gaseous fluid
Flow velocity
> of 4 m/s
Measuring principle
Charge Displacement
Alarm 1 threshold
See table of available versions
Alarm 2 threshold
See table of available versions
Alarm 3 threshold (fault)
Automatically activated by the function of test
Alarm outputs
n. 3 outputs with solid state relay, fuse-
protected auto resetting
Maximum current outputs
100 mA
Maximum applicable voltage
outputs
48 V
Output functions
Adjustable normally closed or normally open.
Common to negative or positive (see wiring
examples)
Probe working temperature
< of 140 º C
Working pressure of the probe
< 2 bar's
Electrode material
Stainless steel aisi 304
Box material
Aluminum
Moisture
< 95% Non Condensing
Room temperature for electronics
-20 / +60 º C
Dimensions
DIN A
Measurable elements
All Non-Aggressive Gases
Electrical connection
3-Pin Terminal Block 1 + 1 6-Pin Terminal Block
Mechanical connection to the
structure
3/4" G
Degree of protection
IP 65
Display
n. 4 led
PWM output 4/20 mA
Active Output, Optoisolated. Max Load 500 Ohm
Serial output
RS485 2-Wire
Certifications
CE/AtEx zone 22 D upon request