3
Install Natural Gas(NG) Regulator and 12 Foot Hose
Connect the NG regulator to the inlet of gas manifold. (
See Fig. 4
)
Connect the swivel nut of the 12 ft. NG hose to the vertical fitting of the NG Regulator.
WHEN YOU FINISHED THIS STEP, PLEASE SKIP TO STEP 6.
NOTE:
Make sure the 12 ft. NG hose stays away from sharp edges.
Gas Manifold
NG Regulator
Swivel Nut
of 12' Hose
Vertical fitting
Fig. 4
Install Regulator, Tank Tray Set and Liquid Propane(LP) Gas Tank
4
Pan Head Screw
3/16"x3/8"
Qty. 5
Part # S182G03061
Island Bottom Panel
LP Gas Tank
Fig. 5
Regulator hose connector
5/8" UNF male thread
Clamp
(Not provided)
Stainless Steel Flexible Connector (Not provided) must
compy with the Standard for connectors for Outdoor Gas
Appliances and Manufactured Homes, ANSI Z21.75
•
CSA
6.27, and suitable for outside installation. The maximum
length of the connection shall be 6ft.(1.82m).
On the proper location, drill 2 holes on the island left side panel for installing the regulator hose connector.
Then install the regulator using 2 Pan Head Screws 3/16"x3/8" and tighten securely.
On the proper location, drill 3 holes on the island left bottom panel for installing the tank tray set. Then install
tank tray set using 3 Pan Head Screws 3/16"x3/8" and tighten securely.
Connect the stainless steel flexible connector to the manifold and regulator, then use a clamp to hold the
stainless steel flexible connector as shown for securing.
Place the LP gas tank into the tank tray set. Make sure the tank valve facing the right rear corner of left island.
Tighten the wing bolt to secure the LP gas tank. (
See Fig. 5
)
Connect the LP regulator onto the LP gas tank.
CAUTION:
There shall be a minimum clearance of 2 inches (50.8 mm) between the floor of the LP-gas cylinder
enclosure and the ground. Proper ventilation must be added to the island.
Gas Line
NOTE:
To comply with the standarad, built-in appliance for use with a remote self-contained LP gas supply
system must use rigid pipe,semi-rigid pipe or a connector complying with the
Standard for Connectors for
Gas Appliances, ANSI Z21.24/CSA 6.10
, or the
Standard for Connectors for Outdoor Gas Appliances and
Manufactured Homes, ANSI Z21.75/CSA 6.27
to connect the remote self-contained gas supply system. For
safety, we suggest to use a stainless steel flexible connector as shown. But, if using semi-rigid tubing, do
not use materials made of aluminum or aluminum alloy tubing. The connector should be installed at the location
visible when opening the door.
Tank Tray Set