LIMITED WARRANTY 

 
Turbinaire. warrants to the original purchaser that the Turbinaire equipment described in this manual will 
be  free  of  defects  in  materials  and  workmanship  for  a  period  of  TWO  (2)  YEARS  from  the  date  of 
purchase of a single speed model HVLP sprayer and THREE (3) YEARS from the date of purchase of a 
variable  speed  sprayer.  Turbinaire’s  only  obligation  shall  be  to  repair  or  replace,  at  its  option,  such 
product  proved  to  be  defective  during  the  warranty  period.  This  warranty  is  subject  to  the  timely 
notification and substantiation that such products have been stored, maintained and used in accordance 
with the Turbinaire. written instructions. A proof of purchase is required for all warranty claims. 
 
Customers  returning  goods  to  Turbinaire.  or  an  authorized  service  center  for  warranty  claims  will  be 
asked  to  prepay  freight  charges  within  reason.    Goods  returned  to  Turbinaire. or  an  authorized  service 
center for repair or maintenance must be clean and free from paint to allow for inspection.  Should any 
equipment  require  cleaning,  a  charge  will  be  made  whether  or  not  under  warranty.    Failure  to  change 
filters  as  needed  and  the  use  of  parts  other  than  genuine  Turbinaire  replacement  parts  that  cause 
damage to the unit will void the warranty.  
 
All  statements,  technical  information  and  recommendations  enclosed  are  based  upon  tests  that 
Turbinaire.  considers  reliable.  However,  neither  the  seller  nor  the  manufacturer  shall  be  liable  for  any 
injury, loss or damage, direct or consequential, arising from the use of the product or the inability to use 
the product. Before use, users shall determine the suitability of the product for his/her intended use.  The 
user assumes all risk and liability whatsoever in the use or failure to use the product, whether due to a 
product defect or not. Turbinaire’s only obligation shall be to replace or repair, at its option, the quantity of 
product  proved  to  be  defective  and  any  consequential  damages  shall  be  limited  to  the  volume  of  the 
Turbinaire equipment purchased. 
 
Except where prohibited by law, this warranty is exclusive and is in lieu of all expressed or implied rights, 
warranties and conditions, statutory or otherwise. 
 
For further information, please contact Turbinaire directly at: 
 
 

Canada (Head Office): 

291 Shannon Street, suite#201 
Montreal, QC 
H3C 2J6 

  

Tel:  (514) 396-5099 
Fax: (514) 396-0695 
 
E-mail:  

[email protected]

 

Internet:  http://www.turbinaire.com 

 
 
 
 

Summary of Contents for 1245GT

Page 1: ...Features for the expert Ease of use for the beginner OPERATOR S MANUAL Turbine Powered HVLP Sprayers...

Page 2: ...TIONS CAUTION Arcing parts Keep the turbine at least 20 feet away from explosive vapors to avoid risk of fire or explosion Only connect the power cord to a grounded circuit Never spray flammable mater...

Page 3: ...r outlet for increased versatility With no compressor or complicated hook up required the user is free to spray virtually anywhere Simple design makes Turbinaire systems easy to learn use and particul...

Page 4: ...way from the spray area as possible and plug into a standard power outlet 2 Uncoil the 25 air hose and install it hand tight to the turbine air outlet If you purchased TSG 3295 optional 5 Heavy Duty H...

Page 5: ...red the viscosity use the chart below to choose the proper size Atomizing Kit for the material to be sprayed and install it on the gun ATOMIZING KIT SELECTION CHART The proper size Atomizing Kit is cr...

Page 6: ...NOT remove the cup from the gun when connected to the hose and the turbine is on As a non bleeder the BNB gun has a two stage trigger the first stage releases air through handle and the second stage r...

Page 7: ...h on a test piece THE VARIABLE SPEED CONTROLLER VSC Most coatings do not require maximum air volume to be atomized All Turbinaire systems equipped with a VSC have a three way power switch On Off On Wh...

Page 8: ...s material in the cup You may tilt the gun as necessary to spray a ceiling or table top for example but note that the Pressurization Tube that pressurizes the cup must remain clean in order to push th...

Page 9: ...e material in the cup if it is catalyzed or has a limited pot life When you are finished your spraying project remember that the cup remains pressurized even after the turbine is shut off and the gun...

Page 10: ...ect the performance of your system when used CAUTION Do NOT submerse entire gun body in solvent or cleaning solutions There are internal o rings gaskets that do not come in contact with coatings being...

Page 11: ...tinue spraying C Use Atomizing Kit that allows for working with trigger fully engaged D Ensure that Needle and Fluid Tip are same size at all times Fluid Leaking From Paint Cup and or Bubbling In Pain...

Page 12: ...ase air pressure in tank to flush hose D Remove kink and straighten as necessary E Tighten Wing Nuts on paint tank or replace gasket if necessary F Check level and add Paint Leaking From Fluid Tip A D...

Page 13: ...E Adjust turbine air volume output using VSC F Reduce air temperature in spray area and or add retarder or flow agent to material Fish Eyes Small round depressions in the paint film Normally form as s...

Page 14: ...r not under warranty Failure to change filters as needed and the use of parts other than genuine Turbinaire replacement parts that cause damage to the unit will void the warranty All statements techni...