Additional power supply for SmartController 7000 – Safety Connector
In case of a power failure, the SmartController no longer controls any output. If flow pumps are connected to
a safety connector 6105.500 (14), the SmartController 7000 must also be connected to a safety connector
(possibly same battery with 12 V).
The Safety Connector enables a normal operation with the TUNZE
®
power supply unit (15), but in case
of a power failure it will automatically switch over to a battery (16) or a DC power source. It should always
be ensured that the battery is in an optimal condition, by using a commercially available battery charger.
Indoor use of lead starter batteries for cars is inadmissible!
Never connect the SmartController 7000 directly to a battery or other DC power source or without a fuse!
The maximum DC voltage is 18 volts (switch-off limit) - if exceeded, the electronics will be destroyed!
A
B
24V
+
+
+
+
+
+
+
12V
OR
OR
SmartController
7000
4
H
ig
h T
ec
h A
qu
ar
iu
m
Ec
ol
og
y
Combinations
A switching socket or a valve can also be combined with a
Y-cable. Therefore it is possible to control 3 different devices
through a single socket.
Combinations:
(A) switching Y-cable + pump + LED 8850
(B) switching socket or valve + Y-cable + 2 pumps or
2 LEDs 8850
If a switching socket or valves are connected to a socket
together with pumps or LEDs 8850, make sure that the
switching socket or the valve is always connected first, and
then the pump or LED 8850 light only connected afterwards to
the supplied connector sockets of the switching socket / valve.
Y-cable
With the Y-cable 7090.300 (10), a further device can be
connected to a socket. Through this, two different devices
can be simultaneously controlled on a single socket (c), for
example, a Turbelle
®
pump and a TUNZE
®
LED 8850 (11).
Alternatively, two pumps (12) or two LEDs 8850 (13) can also
be operated on a single socket. With 4 Y-cables it is thus
possible to connect 8 Turbelle
®
pumps or 8 TUNZE
®
LEDs
8850 to the SmartController 7000 (5).
Caution!
When using a Y-cable it is only possible to connect
identical dimming LED lights with the same voltage, for
example, 2 x 8850.000 with 24 V (13a), or 2x 8810.000 /
8820.000 / 8830.000 with 12 V (13b). A combination of these
two lamps will destroy the 12 V lamp!
Switching socket /
CO
2
valve
The switching socket (Controlled Power Socket) 7070.120 (1)
and the CO
2
valve (2) from the CO
2
valve set 7070.200 each
have a connection (a) for the SmartController 7000 (3) and a
socket (b) for connecting additional TUNZE
®
LED 8850 (4) or
a Turbelle
®
pump (5).
Therefore, without an additional cable a switching socket (1)
or a valve (2) can be operated on a single socket / channel (c)
of the SmartController 7000 (3) together with a TUNZE
®
LED
8850 (4) or together with a Turbelle
®
pump (5).
It is, however,
NOT
possible to connect a switching socket and
a valve to a single socket / channel (c)!
When connecting a CO
2
bottle (6), ensure that the CO
2
valve
(7) and the non-return valve (8) are correctly connected in the
direction of the arrow (9).