SmartController

7000

x7000.8888_E

01/2017

TUNZE

WEB

INTERFACE

TUNZE

HIGH PRECISION

MEASUREMENT

TUNZE

ALL-IN-ONE

SOLUTION

H

ig

h T

ec

h A

qu

ar

iu

Ec

ol

og

y

TUNZE

®

 Aquarientechnik GmbH

Seeshaupter Straße 68

82377 Penzberg - Germany

Tel  +49 8856 2022

Fax +49 8856 2021

[email protected]

www.tunze.com

1

Instructions for use

English

Contents

General information / scope of delivery

Technical data / accessories / spare parts / delivery state 

Switching socket / CO

2

 valve / Y-cable / combinations

Safety instructions / safety instructions for the magnet holder of the pH / mV electrode holder

Safety instructions for TUNZE

®

 power supplies / wall mounting of the SmartController 

Care and cleaning of the electrode

Basic settings with the touch panel – initial start-up

pH / CO

2

 SmartController 7070.000 (setting using the touch panel)

Temperature SmartController 7028.000 / pumps, lamps (setting using the touch panel)

Settings for smart phone, tablet, or PC with WiFi 

Integration into an existing WiFi network in the Access Point Mode

Integration into an existing WiFi network in the Client Mode

Reset of the Client Mode / important notice in case of incorrect depiction

Connecting multiple SmartControllers in the Access Point Mode / Client Mode

Access to the SmartController via the Internet / menu “Pumps”

Pulse mode – wave motion simulation

Interval mode – high and low tide simulation

Menu “Lamps” – lamp 1

Menu “Lamps” – season

Menu “Measurement”

Warranty / disposal

Page

2

3

4

5

6

7

8

9

10

11

11

12

13

14

15

16

17 - 19

20

21

22 - 23

24

Summary of Contents for SmartController 7000

Page 1: ...troller Care and cleaning of the electrode Basic settings with the touch panel initial start up pH CO2 SmartController 7070 000 setting using the touch panel Temperature SmartController 7028 000 pumps lamps setting using the touch panel Settings for smart phone tablet or PC with WiFi Integration into an existing WiFi network in the Access Point Mode Integration into an existing WiFi network in the...

Page 2: ... with 4 connection cables each with a length of 1 2 m 47 2 in Mounting set Suitable for devices with Wi Fi and browser Dimensions without mount L x W x H 133 x 33 x 116 mm 5 2 x 1 2 x 4 5 in Up to 8 pumps or 8 LED 8850 lights are controlled with the separately available Y cable 7090 300 7 not included in the scope of delivery Ambient temperature 0 45 C 32 113 F General information The TUNZE SmartC...

Page 3: ...Redox test solution 475 mV 50 ml 1 7 oz 4 7040 200 Cleaning solution for electrodes 5 7070 300 pH mV electrode holder 6 7070 100 pH electrode plastic 7 7070 110 pH electrode glass 8 7055 100 mV electrode glass 9 7070 200 CO2 valve set 10 7070 120 Controlled Power Socket 11 7097 050 Moonlight Turbelle 12 6105 500 Safety Connector mV with Controlled Power Socket 7070 120 with mV electrode 7055 100 M...

Page 4: ... is always connected first and then the pump or LED 8850 light only connected afterwards to the supplied connector sockets of the switching socket valve Y cable With the Y cable 7090 300 10 a further device can be connected to a socket Through this two different devices can be simultaneously controlled on a single socket c for example a Turbelle pump and a TUNZE LED 8850 11 Alternatively two pumps...

Page 5: ...the Magnet Holder always use the supplied spacer adapter Heating above 50 C 122 F will lead to the destruction of the magnet or loss of the magnetic effect 10 Safety instructions Thee connection to third party devices for example to a different power supply or switch is not allowed 1 Only use the SmartController 7000 in aquariums whose operation is also permitted outdoors 2 Before putting the powe...

Page 6: ... controller Safety instructions for TUNZE power supply units TUNZE power supply units have not been designed for outdoor operation 1 Inordertopreventwaterdamage thepowersupplyunitshouldbe placed as far away from the aquarium as possible Operation is permitted only with a residual current operated circuit breaker fitted max 30 mA Before working in the aquarium please make sure that all electric uni...

Page 7: ...ing solution for about 10 minutes 3 Then rinse with very clean water aqua dest and dry with very soft paper 4 Service life of the electrode If a clean electrode is properly stored the self discharge consumption is lower than when it is used in measuring media Therefore the electrode tip should always be kept moist between the measurements and preferably stored in a KCl solution The electrode has a...

Page 8: ... up down keys to set the time Save with enter Enabling the food timer Press back for 5 seconds It also works if the parental lock is activated Select temperature scale Back to the menu then up then press enter again and choose between Celsius and Fahrenheit Save with enter Select language Back to the menu then up then press enter again and choose between German and English Save with enter Note The...

Page 9: ...ous program step can be reached Press on upward or downward until 5 7 calibration appears in the display When pressing enter an automatic calibration will be performed with the pH buffer for pH 7 and pH 5 The second row of the display will then show pH 5 enter First clean the electrode with a cleaning solution and wipe down or let it drip off thoroughly Immerse the electrode in calibration solutio...

Page 10: ...w possible to directly specify the respective set point temperature It can be set with up or down and stored with enter Devices for cooling e g fans or refrigeration units must be connectedtoaswitchingsocket7070 120 2 onchannel 3 second socket from the left Devices for heating must be connected to an additional switching socket 7070 120 2 on channel 2 second socket from the right However please ob...

Page 11: ...shed open the browser of the smart phone tablet or PC and enter the address 192 168 2 1 The website of the SmartController 7000 2 will now open and allow the performance of settings 4 The first connection can take several minutes First select one of the available languages 3 then click on the Settings menu item 4 Settings menu Time and date 5 as well as the language are shown on the display of the...

Page 12: ...uter of the network the SmartController 7000 can be found on the network with the help of a utility software If the Bonjour service from Apple is installed the SmartController 7000 can be found by entering smartcontroller local in the browser With Windows and Apple devices this utility software can be downloaded from Apple for example from https support apple com on the Internet The Bonjou service...

Page 13: ...entry for this address after the language selection At the end press Take over Reset of the Client Mode If a connection to the specified network in Client Mode has not been found through the browser then the assigned network should be switched off or SmartController 7000 switched on outside of this network If the SmartController 7000 is unable to successfully connect with the existing network in t...

Page 14: ...2 2 can be used for the second device Before you confirm the setting for the Client Mode the first SmartController 7000 must now also be switched on 2 It will then work as master For additional SmartControllers which are to be operated simultaneously in the Access Point Mode the procedure is the same as with the second SmartController 7000 The last number in the IP address is then counted up by on...

Page 15: ...e In order to reach the SmartController 7000 outside of the in house WiFi network an external access to the router must be enabled For example this can be performed through a secure VPN connection This may however entail security risks and thus requires advanced computer skills Theconnectionismadepossiblethroughthebuilt inOpenVPN server 2 To do this the data of the port or a DynDNS must be entered...

Page 16: ...r 7000 page in the browser and select a language 4 When you click on the menu item Pumps 5 the black button Pulse mode 6 will be displayed during the first opening Field General settings 7 With the Pulse mode 6 button activated the time between minimum and maximum circulation performance of the pumps 8 can be set here simultaneously for all 4 channels pumps with the top regulator This will generat...

Page 17: ... SmartController 7000 page in the browser and select a language 4 When you click on the menu item Pumps 5 the black button Pulse mode 6 will be displayed initially during the first opening Click this black button and select Interval Mode 6b The pumps will now be controlled alternately for example the right pump in the aquarium once and then the left pump once On the SmartController 7000 the channe...

Page 18: ...els 3 and 4 can simultaneously be set to synchronous or alternating asynchronously If the pumps waveboxes are adjacent and they should be switched asynchronously the function Channel 4 and 3 in the inverse operation if will be activated the regulator is pushed upwards 7 Otherwise leave the regulator down Clicking on the Auto adjust start 8a button will enable an automatic search for detecting the ...

Page 19: ...rning after the time has expired the selected pulse operation of the pump will start again in the Pulse mode see page 16 Effect of Interval mode in the aquarium The interval operation between low tide channels 1 and 2 and high tide channels 3 and 4 enables the creation of two annular flows in the aquarium The reef rock is regularly flooded from both sides the sediments are washed away and the inve...

Page 20: ...ference in practice instead of a separate setting for each individual lamp each individual light channel Any changes to the course of the day for the other lights light channels separate adjustments can still be performed individually after the setting of lamp 1 and the subsequent transfer to the other lights Field Moonlight settings 9 Regulator Enable moonlight 9a By switching on the Enable moonl...

Page 21: ... lamp brightness throughout the course of the year 5 In this field it is possible to control the entire light intensity throughout the year For this purpose there is a cursor 6 for each month or a dark blue button 7 Here the course of the year can be set either by directly dragging the points on the graph 6 or by pressing the dark blue buttons 7 The function is particularly interesting for aquariu...

Page 22: ...nd controlled according to a specified value The mV electrode 7055 100 9 can be corrected adjusted with the Redox Test Solution 475 mV 50 ml 1 7 oz 7075 150 10 and the displayed mV value with the lowest function of the field 11 Function pH 6b The current pH value will be shown 12 By activating this function the channel 4 of the SmartController 7000 8 will be activated as pH controller and controll...

Page 23: ... Channel 3 can be activated as a switching socket for the cooling and controlled according to a specified value The lights can dim even at high temperatures or even be switched off 18 Heat defence 19 The activation of this function will cause that from an aquarium water temperature of 30 C 86 F only the moonlight will be active and only the night mode will continue to work for the Turbelle pumps i...

Page 24: ... manufacturer Exclusion from guarantee shall exist also in case of damage caused by inexpert handling such as water damage technical modification carried out by the buyer or by connection to devices which have not been recommended Subject to technical modifications especially those which further safety and technical progress Customers in USA please refer to seperate Limited Warranty for United Sta...

Reviews: