WWW.TUCKERAUTO-MATION.COM
INSTALLATION
GUIDE
KP
evo
- TAP CONTROLLER
920.1003.02 | 17
24
Consecutive obstacles in closing
- Remove the obstacle in closing.
- Make sure that the leaf has been mounted correctly and that it moves smoothly,
remove any friction
26
Lock failure
- Check the wiring of the lock
- Check that the maximum load of the lock has not been exceeded
- Replace the lock
- Replace the
Logic
board
27
Motor rotation fault
- Check the polarity of the motor cable
31
Consecutive obstacles in opening
- Remove the obstacle in opening
- Make sure that the leaf has been mounted correctly and that it moves smoothly,
remove any friction
39
Setup
data missing or corrupted
- Perform Setup
-
Replace the
Logic
board
O
6
.
2
THER BOARD DATA
Go to menu 2.5.11 of the KP EVO. The display provides
information on the following parameters:
-
V MAIN : input voltage to the
Logic
board (Volts)
-
V ACC : output voltage for accessories (Volts)
-
POS : position of the rotating shaft (degrees)
-
I MOT : current drawn by motor (Amperes)
2.7 FIRMWARE VERSIONS
Go to menu 9 of the KP EVO to view the firmware
versions of the bootloader, the
Logic
board and the
KP EVO.
2.8 LOG DATA
The 950N2 records the last 512 system events. A
battery must be installed on the
Logic
board in order
to save the list of events in memory even if the system
is switched off.
To download the data as a text file, see § .