920.1020.15
24
*** Tucker Auto-Mation recommends the use of a door-mounted secondary activation device
when dip switch 9 is ON - Enabled.
Description
ON
OFF
1
Closed Door Force
Additional force applied while door is
in closed position. Be sure to maintain
ANSI compliance if using on low
energy application. Cannot exceed 30
lbf to get door moving from jamb.
Disabled (Default)
2
Push / Pull Arm
Slide Arm Application. Operator
stroke at 90
°
degrees or less. Visible
change in performance may not
always be noticeable.
Push Arm Application.
Operator stroke 90
°
or
greater. (Default)
3
Night Function (Exit
Only)
Allows activation at input 10 when
On-Off switch is in OFF (night
function) position.
Disabled. The On/Off
switch, when OFF, requires
manual operation of the
door. (Default)
4
Push and Go
Enabled
Disabled (Default)
5
Full Power / Low
Energy
Low Energy performance enabled. 5
seconds to open, 7 seconds hold
open, 5 seconds to close. Speed &
time potentiometers are disabled.
Settings are fixed.
Disabled. Control can be
adjusted for full power or
low energy operation via
potentiometers. (Default)
6
Lockout Function
Overhead presence sensor input (17)
is inhibited during closing cycle unless
input 14 is triggered. Connect COM
and Input 14 to NC output of lockout
safety beam.
Disabled. Overhead
presence sensor input (17)
is inhibited during closing
cycle. Otherwise, if
commanded, it keeps an
open door open and a
closed door closed. A
command at Input 14 will
stall the door. (Default).
7
Inhibit at 30
Degrees Before
Door Fully Open
Input is disabled at 30 degrees prior to
full open door position. Eliminates
need for external inhibiting switch.
Stall function remains un-
inhibited for full door
stroke. (Default)
8
Power Close
Additional closing force applied for
final 10 degrees of closing.
Disabled (Default)
9
Assisted Manual
Closing***
Enabled assisted closing following a
manual opening
Disabled assisted closing
following a manual opening
10
FACTORY USE ONLY