WWW.TUCKERAUTO-MATION.COM
INSTALLATION
GUIDE
KP
evo
- TAP CONTROLLER
920.1003.02 | 23
1 5
1 6
950N2
Master
interlock
ID=1
950N2
Slave
interlock
ID=3
6.1
INTERMODE
1 5
shows the
ID
to assign to the 950N2 units in
the network.
The system consists of a
Master
unit and a maximum
of 14 Slave units. The 950N2
Master
unit is the only
one on which the operating mode should be set, which
is then also applied immediately to all the Slave units.
With
INTERMODE
, it is not possible to change the
operating mode of an individual unit.
950N2 The
Master
must be assigned
ID
1 and the Slave
units with
ID
from 2 to 14.
6.2
INTERLOCK
1 6
shows the
ID
to assign to the 950N2 units in
the network.
Either of the two units can be designated as the
Master
and the other as the
Slave
. In
INTERLOCK
mode, one
door can open only if the other is closed. The available
variations are shown below.
If the PARTIAL mode is associated with
INTERLOCK
,
only the
Master
leaf opens.
Connect the devices and carry out the programming
and
Setup
of the individual
950N2 units before
configuring the
INTERLOCK
using KP EVO.
Select
on the
Master
unit to activate the
INTERLOCK
.
950N2
MASTER
ID=1
950N2
SLAVE
ID=2
950N2
SLAVE
ID=15
950N2
SLAVE
ID=3