- 13 -
FOR PERMANENT CONNECTIONS to natural gas or a fixed propane supply, an
authorised person, in accordance with these instructions, local gas fitting
regulations, municipal building codes, the AGA installation code AS5601 and any
other relevant statutory regulations, must be employed.
For connection to a natural gas bayonet fitting, a gas regulator must be fitted at the
inlet of the appliance, and an approved 10mm, class A, natural gas hose (no longer
than 2 metres), going from the gas regulator to the bayonet point, complying with
AS1869 must be used.
It is recommended that an isolation valve and union be fitted before the barbecue
or side burner; refer AS5601/ AG601 for correct pipe sizing to ensure adequate gas
is supplied to the appliance.
For natural gas check the pressure of the regulator, and adjust if necessary to the
pressure shown on the data plate.
CONVERSION PROCEDURE
FOR AUTHORISED INSTALLER
PROPANE GAS TO NATURAL GAS CONVERSION.
Disconnect and disassemble burner.
Remove injectors and replace with the correct size injectors see the data plate or
instructions.
Re-assemble burner.
Replace the PROPANE GAS hose and regulator with an approved natural gas
regulator and hose.
Turn the gas on and test the appliance for leaks, repair if necessary.
Light the burner and set the pressure at 1 KPA.