![Tsun TSOL-ACU3.0K User Manual Download Page 48](http://html1.mh-extra.com/html/tsun/tsol-acu3-0k/tsol-acu3-0k_user-manual_1178520048.webp)
46
8 Battery maintenance
8.1 Transportation
Lithium batteries are dangerous goods. Passed the test of UN38.3, this product meets
the transportation requirements for dangerous goods for lithium batteries. After the
installation of the battery on site, the original packaging (contains the lithium battery
identification) should be kept. When the battery needs to be returned to the factory for
repair, please pack the battery with the original packaging to reduce unnecessary trouble.
8.2 Storage
After purchasing the battery, please store it with following instructions:
1) Please store it in a dry and ventilated environment, keep it away from heat
sources.
2) Please keep it in an environment with storage temperature as -20 ° C ~ 50 ° C,
humidity <85% RH.
3) For long-term storage (>3 months), please put it in an environment with a
temperature of 18 ° C to 28 ° C and a humidity of < 85% RH.
4) The battery should be stored in accordance with the storage requirements
mentioned above, and the battery should be installed within 6 months since
delivered from the factory and used with compatible inverters.
The battery cannot be disposed of as household refuse. When the service life of the
battery reaches to the limit, it is not required to return it to the dealer or TSUNESS, but it
must be recycled to the special waste lithium battery recycling station in the area.
8.3 Cleanliness
Clean the enclosure lid, LCD and LED indicator of the inverter with moistened cloth with
clear water only. Do not use any cleaning agents as it may damage the components.
Note
!
The battery remains 40% power when it is sent from the factory.
The longer the battery is stored, the DOD value is getting bigger. When
the battery remaining voltage fails to reach the startup voltage
requirement, the battery may be damaged.
Judgment condition: Close the battery breaker switch and press the
BMS switch. At this time, if the LED light is flashing, it is running
normal. If the LED light is off, the battery is in faulty.
Summary of Contents for TSOL-ACU3.0K
Page 1: ...31 TSOL ACU3 0K...
Page 44: ...42 4 Click Add a New Gateway Logger and input the SN of the monitor logger...
Page 49: ...47...