11
Trumatic S 3002 (P)
4. Place the casing onto the lower retaining shackles. Guide
the pressure rod (11) from below into the handle connector
(26) and engage the casing at the top. Push the operating
handle (55) from above onto the pressure bar (11) in such a
way that the arrow points to the “0“ position.
Trumatic S 5002
4. Place the casing onto the lower retaining shackles. Guide
the pressure rod (11) with operating handle (55) from below
into the handle connector (26) and engage the case at the top.
Front case with flame effect
Electrical connection 12 V
Electric cables, switching units and control units for heaters
must be arranged in the vehicle in such a way that their satis-
factory operation cannot be adversely affected under normal
operating conditions. All cables leading to the outside must be
splash proof at the leadthrough opening.
Connect provided cable (1.5 m) to fuse-protected on-board
power supply (5 A central electrical system). The polarity is
not important.
No other consumers must be connected to the supply line!
When power packs or power supply units are being
used, note that the output voltage is between 11 V and
15 V and the alternating current ripple is < 1.2 Vpp. We rec-
ommend the automatic chargers from Truma for the different
applications. Please ask your dealer. Other chargers may be
used only with a 12 V battery as a buffer.
Route 12 V supply line along the floor towards the rear and at-
tach to the heater pedestal using the provided clip.
+ 12 V
Control panel
The front case with flame effect is designed for standard right-
hand installation. The control panel must be moved to the
right-hand side of the front case with flame effect if left-hand
installation is required.
To do this, detach cable from control panel, push both catches
together and remove control panel. Push control unit into
right-hand side. Then route cable along right-hand side of
front case to control panel as shown in figure.
12 V
Fitting the front case
Connect 12 V supply line to electronic system (connect plug
so that both plug wires are routed downwards). Engage sup-
ply line in clip (d) at bottom of front case. Place the casing
onto the lower retaining shackles. Guide the pressure rod (11)
with operating handle (55) from below into the handle con-
nector (26) and engage the case at the top.
d
12 V
Function check
After installation, the sealing tightness of the gas feed
line must be tested in accordance with the pressure
drop method.
A test certificate (in Germany, for example, in
accordance with the DVGW operational data sheet G 607) is
to be issued.
Following this inspection, test all functions of the appliance as
specified in the operating instructions.
The operating instructions and completed guarantee card are
to be given to the owner of the vehicle.
Warning information
The installer or vehicle owner must display the yellow sticker
with the warning information, enclosed with the appliance, in
the vehicle so it is clearly visible to all users (e.g. on the ward-
robe door)! Ask Truma to send you a sticker if necessary.