TRUE RESIDENTIAL
®
TEC_TM_073 | REV. D | EN
12/03/2021
Page 46 of 56
WATER FILTER REPL ACEMENT
The built-in water filter is designed to filter sediment,
remove unpleasant taste and odor and inhibit scale.
Filter life expectancy is twelve months for low-scale
water and six months for high-scale water.
The ice machine monitors how long the filter has
been in operation and will display “FLT” when the
filter needs to be replaced. Replacement water filters
are available through your True dealer.
THE ICE MACHINE WILL NOT MAK E ICE IF THE
WATER FILTER IS NOT INSTALLED.
1. Press and hold “CLEAN” and “LIGHT” to reset the
filter reminder.
2. Rotate the water filter counterclockwise and pull
the filter from the unit.
WA RNING:
T RUE RECOMMEND S T URNING
OFF T HE WAT ER SUPPLY BEFORE
REPL ACING T HE WAT ER FILT ER T O PRE V EN T
WAT ER FILT ER DA M AGE OR L E A K S
NO T E: IF T HE WAT ER FILT ER WIL L NO T T URN
OR IS DIFFICULT T O REMOV E, PRE S S A ND HOL D
T HE PO W ER BU T T ON UN TIL T HE DISPL AY SHO W S
“FIL”. T HEN, PRE S S A ND HOL D T HE PO W ER
BU T T ON UN TIL T HE DISPL AY SHO W S “OFF”.
3. Insert the replacement water filter and rotate the
filter clockwise.
NOTE: LUBRICATE THE FILTER O-RINGS
PRIOR TO FILTER INSTALL ATION.
4. Verify the water supply is on.
5. Press and hold the power button until the display
shows “FiL”.
KICKPLATE
REPL ACEMENT PARTS
True maintains a record of the serial number
for your unit. If at any time during the life of
your unit, a part is needed, you may obtain
that part by furnishing the model number and
serial number to the company from whom you
purchased your machine.
For replacement parts contact your True dealer
or call True parts department at 844-849-6179.
Inquiries can be sent to:
(636) 240-2400 • toll free (888) 616-8783
CONDENSER CLE ANING
INS TRUC TIONS
• Keeping the condenser coil clean will minimize
required service and lower electrical cost.
• The condenser coil should be cleaned by
removing dust and other build-up from the
tube assembly with vacuum or a clean rag.
1. Remove kickplate.
2. Vacuum or use clean rag to remove dust
build-up from coil.
3. Re-install kickplate.v
Summary of Contents for TUI-15-R/L-OP-B
Page 2: ...TRUE RESIDENTIAL TEC_TM_073 REV D EN 12 03 2021 Page 2 of 56...
Page 6: ...TRUE RESIDENTIAL TEC_TM_073 REV D EN 12 03 2021 Page 6 of 56 NOTES...
Page 8: ...TRUE RESIDENTIAL TEC_TM_073 REV D EN 12 03 2021 Page 8 of 56 NOTES...
Page 10: ...TRUE RESIDENTIAL TEC_TM_073 REV D EN 12 03 2021 Page 10 of 56 NOTES...
Page 16: ...TRUE RESIDENTIAL TEC_TM_073 REV D EN 12 03 2021 Page 16 of 56 NOTES...
Page 40: ...TRUE RESIDENTIAL TEC_TM_073 REV D EN 12 03 2021 Page 40 of 56 NOTES...
Page 54: ...TRUE RESIDENTIAL TEC_TM_073 REV D EN 12 03 2021 Page 54 of 56 NOTES...