INCORRECT.
Ice guide positioned too far inside the water trough.
INCORRECT.
Ice guide positioned outside the water trough.
CORRECT.
Ice guide positioned in the guide channel and flush against the
back side of the water trough opening.
ICE GUIDE
The ice guide sits over the spray nozzles and directs
falling ice into the bin.
REMOVAL
Lift the front of the guide and pull the guide forward.
INSTALLATION
Position the ice guide over the spray bar. To be
correctly installed, the ice guide must–
• Be firmly positioned over the spray bar.
• Sit with its front edge inside the water trough.
• Have its slots aligned with the spray nozzles.