15 INCH TRUE ICE
TM
MACHINE INSTALL GUIDE
TEC_TM_073 | REV. D | EN
12/03/2021
Page 27 of 56
LE VELING ICE MACHINE
1. Set unit in its final location. Be sure there is
adequate ventilation in your room.
2. Proper leveling of your True unit is critical to
operating success. Effective drainage and door
operation will be affected by leveling. Adjust leg
levelers on the front and back of the cabinet if
needed to level the unit.
3. The unit should be leveled from the top of the unit
front to back and side to side with a level. If the
ice machine is not level adjust the stainless steel
leg levelers. The leg levelers can be adjusted by
turning to reach the desired leveling height as
shown in the illustration above.
4. Free plug and cord from back of ice machine
(do not plug in).
5. The unit should be placed close enough to
the electrical supply so that extension cords
are never used.
6. Once installed in final location, attach kickplate to
the magnets on the front of the unit.
WARNING: COMPRESSOR WARRANTIES ARE VOID
IF THE UNIT IS MORE THAN SEVEN FEET (2.1 M)
FROM PLUG-IN CONNECTION OR IF AN
EXTENSION CORD IS USED.
WATER SUPPLY
Locate the water supply.
The water supply line should be connected to the
house supply with an easily accessible shut-off valve
between the water supply and the ice machine. A
reverse osmosis system can be used, provided there
is constant water pressure of 20 psi (1.4 bar) to 80
psi (5.5 bar) supplied to the ice machine at all times.
A copper line is not recommended for this application.
CAUTION: WATER PRESSURE MUST BE BET WEEN
20 PSI (1.4 BAR) AND 80 PSI (5.5 BAR).
A REVERSE OSMOSIS SYSTEM CAN BE USED,
PROVIDED THE WATER PRESSURE STAYS
WITHIN THE REQUIRED R ANGE ABOVE. IF THE
WATER PRESSURE E XCEEDS THE MA XIMUM
PRESSURE, INSTALL A WATER PRESSURE
REGUL ATOR.
A cold water supply line must be supplied to the ice
machine. Use 1/4" OD copper, braided stainless steel
or PEX tubing and compression fittings (not included).
The incoming water temperature must remain between
40°F (4°C) and 100°F (38°C).
Do not connect the ice machine to a hot water supply.
Be sure all hot water restrictors installed for other
equipment are working, such as check valves on sink
faucets, dishwashers, etc.
Insulate the water supply line to prevent condensation.
ELEC TRICAL & PLUMBING
ELECTRICAL
PLUMBING
Voltage: 115/60/1
Water Supply: 1/4” O.D. copper,
braided stainless steel or PEX tub-
ing and compression fittings (not
included)
Drain Pump Connection: Supplied
with 7’ (2.13 m) of 3/8” O.D. plastic
tubing
Min Circuit Ampacity (amps): 15
Power Cord Length: 8' (2.4 m)
Annual kWh Consumption:
9.5 kwh/100 lb
Summary of Contents for TUI-15-R/L-OP-B
Page 2: ...TRUE RESIDENTIAL TEC_TM_073 REV D EN 12 03 2021 Page 2 of 56...
Page 6: ...TRUE RESIDENTIAL TEC_TM_073 REV D EN 12 03 2021 Page 6 of 56 NOTES...
Page 8: ...TRUE RESIDENTIAL TEC_TM_073 REV D EN 12 03 2021 Page 8 of 56 NOTES...
Page 10: ...TRUE RESIDENTIAL TEC_TM_073 REV D EN 12 03 2021 Page 10 of 56 NOTES...
Page 16: ...TRUE RESIDENTIAL TEC_TM_073 REV D EN 12 03 2021 Page 16 of 56 NOTES...
Page 40: ...TRUE RESIDENTIAL TEC_TM_073 REV D EN 12 03 2021 Page 40 of 56 NOTES...
Page 54: ...TRUE RESIDENTIAL TEC_TM_073 REV D EN 12 03 2021 Page 54 of 56 NOTES...