10
EN
vertical heater TES 200
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
1. Proceed as described in the Switch-off section.
2. Clean the device according to the Maintenance chapter.
3. Store the device according to the Storage chapter.
Available accessories
Warning
Only use accessories and additional equipment
specified in the instructions.
Using insertion tools or accessories other than those
specified in the instructions may cause a risk of injury.
Designation
Article number
DualHeat blowing-out tower
Attachment hood for hose
connection
H14 HEPA filter
7.160.000.106
Hygrostat HG 125
6.100.002.042
F7 filter cartridge
7.160.000.449
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to
Trotec for repair.
The device does not start:
•
Check the power connection.
•
Check the power cable and mains plug for damage.
•
Check the mains plug for damages.
•
Check the on-site fusing.
•
Check whether the device is standing upright and on level
ground. The tilt protection may have been tripped owing to
the fact that the device was knocked over. Always put up
the device in an upright position on a suitable, sufficiently
dimensioned surface.
•
The safety thermostat might have tripped due to
overheating Switch the device off and let it cool down for
at least 10 minutes.
•
The room thermostat might be defective. Have a defective
room thermostat replaced by a specialist electrical
company.
•
The overheating protection may have been tripped. Have a
specialist electrical company or Trotec check the electrics
and replace the overheating protection.
The device is loud or vibrates:
•
Check whether the device is set up in a stable and upright
position.
The device gets very warm, is loud or is losing
performance:
•
Check the air inlets and air filters for dirt. Remove external
dirt.
•
From the outside, check the device for dirt (see chapter
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company or by Trotec.
Summary of Contents for TES 200
Page 1: ...TRT BA TES200 TC2020 23 001 EN TES 200 EN ORIGINAL INSTRUCTIONS VERTICAL HEATER ...
Page 15: ...EN 15 vertical heater TES 200 Circuit diagram ...
Page 16: ...16 EN vertical heater TES 200 ...
Page 17: ...EN 17 vertical heater TES 200 ...
Page 18: ...18 EN vertical heater TES 200 ...
Page 19: ...EN 19 vertical heater TES 200 ...