vertical heater TES 200
Operation
Operating elements
10
11
12
13
14
15
16
No. Designation
Meaning
10 Fusing for safety
temperature limiter
Triggers in the event of
overheating
11 Main switch
For switching the device on and
off
12 Connection for
thermostat
•
Temperature measurement
of other rooms when
connected to a ventilation
system
•
If the thermostat is
connected, the room
thermostat inside the device
will be deactivated
13 Operating hours
counter
Indication of operating hours
14 Power cable
connection
Power supply of the device
15 Touchscreen
Selection of programmes and
adjustment of parameters
16
Start/stop
key
Starting the programme
Info
The display will be switched off 3 minutes after it has
been touched. Touching it again will switch it back on.
At temperatures above 60 °C, it will be difficult to read
the display. At temperatures above 65 °C, the display
will be switched off. After the device has cooled down,
the display can be switched back on by touching it
again.
Switching the device on
Warning
The room temperature may increase up to 75 °C
during operation.
If possible, do not stay in the room during the room
heating process. If you feel unwell, exit the room
immediately. Persons sensitive to heat must only stay
in the room after the room has cooled down.
Remove objects and substances not suitable for these
temperatures from the room. Observe the
combustibility of the objects and substances in the
room.
1. Switch the device on by turning the main switch to
position
ON
.
ð
The device initialises.
ð
Please wait
will be indicated on the display.
ð
Once the device has been initialised,
StandBy
will
appear on the display.
2. Touch the centre of the display.
ð
The main selection will appear.
ð
The programme will intuitively guide you through the
operation process.
3. In the
System
section, set the desired language.
4. Select the desired programme.
5. Adjust the target values for temperature, fan speed and
duration for maintaining the temperature.
6. Start the programme by actuating the
On
or
Start/stop
(16)
button.
ð
Heating up
will be displayed.
ð
Once the temperature has been reached, the timer for
the duration to maintain the temperature will start
running.
ð
After the timer has been expired, the device will switch
off automatically.
ð
The fan keeps running for approx. 3 minutes to
dissipate the residual heat from the heating elements.
The device can be restarted without any waiting time.
Switch-off
Warning of hot surface
The room temperature may increase up to 75 °C
during operation.
Note that the surfaces in the room may be hot after the
treatment.
1. Actuate the
Off
or
Start/stop
(16) button on the display.
ð
The fan keeps running for approx. 3 minutes to
dissipate the residual heat from the heating elements.
2. Switch the device off by turning the main switch to
position
OFF
.
Summary of Contents for TES 200
Page 1: ...TRT BA TES200 TC2020 23 001 EN TES 200 EN ORIGINAL INSTRUCTIONS VERTICAL HEATER ...
Page 15: ...EN 15 vertical heater TES 200 Circuit diagram ...
Page 16: ...16 EN vertical heater TES 200 ...
Page 17: ...EN 17 vertical heater TES 200 ...
Page 18: ...18 EN vertical heater TES 200 ...
Page 19: ...EN 19 vertical heater TES 200 ...